22 (70)
6.5.1
EtherTypes
The Anybus CompactCom internally uses bit 12 and bit 13 (mask 3000h) in the EtherType.
Thus the host application cannot implement protocols using Ethertype, where these bits are
used..
The following EtherTypes are used by PROFINET and should not be used by the host
application:
•
8892h (PNIO)
•
88CCh (LLDP)
•
88E3h (MRP)
6.5.2
Multicast MAC Addresses
The host application must not transmit or receive any data from and to the following MAC ad-
dresses as they may be used by the industrial Ethernet network (PROFINET):
•
01-0E-CF-XX-XX-XX
•
01-80-C2-00-00-0E
•
01-00-5E-40-F8-00 ... 01-00-5E-40-FB-FF
•
X3-XX-00-00-00-00
(X: any number 0-F)
6.5.3
UDP/TCP Ports
The following ports may be used by the Anybus CompactCom, and must not be used by the
host application:
•
UDP 67 & 68 (DHCP)
•
UDP 161 (SNMP)
•
UDP 3250 (HICP)
The following ports are reserved for use by PROFINET:
•
UDP 34962 (PROFINET RT Unicast)
•
UDP 34963 (PROFINET RT Multicast)
•
UDP 34969 (PROFINET RPC Context Manager)
•
UDP 53247 (PROFINET RPC Client/Server)
The following ports are reserved for use by EtherNet/IP:
•
UDP 2222 (Implicit messaging)
•
UDP & TCP 44818 (Explicit messaging)
The following port is reserved for use by Modbus TCP:
•
TCP 502 (Modbus messaging)
Anybus
®
CompactCom
™
40 Modbus-TCP
®
Transparent Ethernet Network Guide
SCM-1202-022 1.1