background image

®

P/N 1011504 Rev B 11/18

10

Monthly Cleaning

This unit utilizes an open steam 

generator. When introduced, water 

immediately vaporizes creating a burst 

of steam, leaving behind any minerals 

that had previously been dissolved. 

Though a small amount of minerals are 

necessary for proper operation, exces-

sive amounts will cause poor steaming 

and may damage the generator.
1.  Press the Power button to turn the 

unit off. The unit enters a cool-

down mode and will shut down 

automatically. 

NOTICE

:

 You do not need to wait until 

the cool down mode completes. 

However, the unit will be hot so 

wear heat resistant gloves dur-

ing cleaning.

2.  Put on heat resistant gloves and 

remove the items in Figure 4.

3.  Wash, rinse, and sanitize the items 

removed at the sink. Allow to air 

dry.

4.  Wipe the exterior of the unit and 

the inner part of the basket cavity 

with a clean, sanitized towel. Clean 

up any spills completely. Allow to 

air dry.

5.  Remove wing nut and generator 

cover assembly, generator gasket, 

and diffusers (Figure 5).

6.  Examine all steam generator 

orifices (holes). If mineral deposits 

have formed, place a flat blade 

screwdriver into openings. Use a 

twisting motion to scrape openings 

clean.

NOTICE

:

 Mineral deposits come off in 

“flakes” or in layers if the build-

up is excessive.

7.  Use an abrasive cleaning brush 

and small scraper to remove de-

posits from the generator surface.

8.   Pour delimer solution (not sup-

plied) onto the generator surface 

and allow to soak for one hour.

NOTICE

:

 Be sure to Follow the usage 

instructions on the delimer 

packet.

9.  Remove the delimer solution from 

the generator and rinse with clear 

water to remove traces of delimer.

NOTICE

:

 To ensure proper steaming 

characteristics some mineral 

deposits must be present on 

generator casting.  

If during cleaning, the gen-

erator does become free of 

mineral deposits, add ordinary 

tap water (non reverse osmosis 

or ionic filter system) to casting 

and allow to boil off.

NOTICE

:

 In soft water areas, it may 

be necessary to add a small 

amount of lime to generator 

to “season” it. This will ensure 

proper steaming characteristics 

by producing a thin coating of 

mineral deposits on the casting. 

 

Seasoning mixture consists of 

75 ml. (2-1/4 oz.) baking soda, 

75 ml. (2-1/4 oz.) lime, and 1 

gallon water. Pour 1/4” deep 

of seasoning mixture into a 

cold generator. Turn the unit 

on. After mixture is converted 

to steam, the remaining loose 

powder is removed and genera-

tor cleaned.

10.  Wipe the exterior of the unit and 

the inner part of the basket cavity 

with a clean, sanitized towel. Allow 

to air dry.

11. 

Re-install the diffusers, generator 

cover, generator cover bracket and 

secure with the wing nut.

12.  Re-install all items removed in 

Step 2. 

Figure 5. Steam Generator

Support Channel

Generator Cover 

Assembly

Wing Nut

Diffusers

Steam Generator

Checking and Cleaning Water 

Strainer

To ensure proper and consistent 

steaming results, inspect the water flow 

regulator and strainer cup regularly. 

If the water pressure on the gauge 

has dropped, visually check the clear 

plastic strainer cup and clean out the 

accumulated debris as follows:
1. 

Shut off the water supply valve to 

the unit. Unscrew the clear plastic 

strainer cup and carefully remove 

the mesh strainer screen.

2. 

At the sink, gently flush all of 

the accumulated debris from the 

strainer cup and mesh strainer 

screen. Be especially careful not to 

damage the mesh strainer screen.

3.  Carefully place the mesh strainer 

screen into its seat at the bottom 

of the clear plastic cup and confirm 

that the O-ring is properly seated 

in its place before screwing the 

strainer cup and top back together.

4.  Purge the air out of the strainer 

tubing by disconnecting the male 

quick disconnect fitting from the 

equipment and, over a bucket, 

pushing its valve core in until there 

is a good water flow.

Summary of Contents for RS-1000 INTL

Page 1: ...P N 1011504 Rev B 11 18 Rapid Steamer Manufacturing Number 9100651 Owner s Manual RS 1000 INTL www antunes com IPX3 Rating ...

Page 2: ...or incorrect shipment to the delivery agent Record the model number serial number and installation date of your steamer and keep this information for future reference In Case of Damage If the steamer arrives damaged file a claim with the carrier immediately Save all packing materials when filing a claim Freight damage claims are the responsibility of the purchaser and are not covered under warrant...

Page 3: ...with applicable federal state and local codes Maintenance y y Do not use abrasive materials they can damage the steamer s stainless steel finish y y Do not use corrosive chemicals in this equipment y y Chlorides or phosphates in cleaning agents e g bleach sanitizers degreasers and detergents can permanently damage stainless steel equipment The damage is usually in the form of discoloration dulling...

Page 4: ... C B Specifications Mfg No Volts Watts Amps Hertz Plug Description Plug Configuration 9100651 200 240 5000 30 50 60 HRN IEC309 Electrical Ratings Mfg No A Width B Depth C Height 9100651 17 39 441 7mm 16 86 428 24mm 12 79 324 87mm ...

Page 5: ...trol for the unit Treat the GUI interface with the same care as you would any touchscreen device Do not use tools or objects on the GUI Do not scratch or damage the GUI Figure 1 Components Steam Baskets Water Pan Basket Liner Assembly Basket Riser Top Cover Steam Vent Assembly Graphical User Interface GUI Power Button Water Flow Regulator Touchscreen Icons Increase Used to increase a value Increme...

Page 6: ...food item you are cooking is already shown on the display you can simply press it 6 The unit begins the cooking cycle The display shows the time re maining in the cooking cycle and beeps when cooking is complete 7 Remove the basket s from the unit and continue with food prepa ration as required 8 When cooking is complete the unit returns to the Ready screen Power Button Touchscreen GUI DISPLAY Fig...

Page 7: ...ime The length of time in minutes and seconds for the full cooking cycle You can also press Cancel to cancel the edit and return to the Select Function screen Edit Menu Item Add Menu Item Cancel Copy Menu Item Factory Reset Delete Menu Item Creating New Menu Items Creating new menu items follows the same procedure as editing an existing menu item The only difference is that you press Add Menu Item...

Page 8: ...ith a USB interface on the back of the unit This allows you to load menu items into the system To load a menu file Make sure the unit displays the Ready or Heating screen Insert the USB memory stick loaded with the electronic menu file into the USB connection Figure 3 1 Press Tools to open the Tools screen 2 Press USB Import The system reads the USB device and displays a list of acceptable menu fi...

Page 9: ... Press the Power button to turn the unit off The unit enters a cool down mode and will shut down automatically NOTICE You do not need to wait until the cool down mode completes However the unit will be hot so wear heat resistant gloves dur ing cleaning 2 Put on heat resistant gloves and remove the items in Figure 4 3 Wash rinse and sanitize the items removed at the sink Allow to air dry 4 Wipe the...

Page 10: ...es become free of mineral deposits add ordinary tap water non reverse osmosis or ionic filter system to casting and allow to boil off NOTICE In soft water areas it may be necessary to add a small amount of lime to generator to season it This will ensure proper steaming characteristics by producing a thin coating of mineral deposits on the casting Seasoning mixture consists of 75 ml 2 1 4 oz baking...

Page 11: ...tion Unit displays system error FRAM Control board is inoperable Reset the unit If the problem persists contact your maintenance person or Authorized Service Agency for service Unit displays system error Database Failure Possible data corruption on the receipts Do a factory reset from the Menu Items menu to reset stored receipts Reenter any missing receipts Unit heats but little or no steam is pro...

Page 12: ... P N 1011504 Rev B 11 18 12 Wiring Diagram ...

Page 13: ...ervice Warning 1 33 1001062 Label Water and Waste Conn 1 34 1001213 Label Shock Hazard 1 35 1002726 Label Control Panel 1 Item No Part Description Qty 36 1002778 Label Wiring Diagram 1 37 1031402 Spec Label 9100651 1 38 2120276 Spacer k 3 16 OD x 5 32 4 39 2140101 Adhesive Sealant RTV 1 40 2140144 Tape Pipe Thread 2 41 2180514 Clamp Cable Polypropylene 1 42 2190240 Pipe PTFE 2 43 3000102 Nut Speed...

Page 14: ... P N 1011504 Rev B 11 18 14 Replacement Parts 48 6 22 17 1 14 ...

Page 15: ... P N 1011504 Rev B 11 18 15 Replacement Parts Sheet 2 55 12 15 14 52 15 12 55 47 41 25 60 55 42 40 52 51 49 9 9 52 50 62 53 65 3 ...

Page 16: ... P N 1011504 Rev B 11 18 16 Replacement Parts Sheet 3 20 14 54 30 18 52 31 43 59 63 45 44 61 46 64 38 35 66 ...

Page 17: ... P N 1011504 Rev B 11 18 17 Replacement Parts Sheet 4 29 10 52 28 54 56 58 5 26 14 23 ...

Page 18: ... P N 1011504 Rev B 11 18 18 Replacement Parts Sheet 5 2 52 24 36 13 4 24 52 ...

Page 19: ... P N 1011504 Rev B 11 18 19 Replacement Parts Sheet 6 57 27 7 16 21 19 11 52 ...

Page 20: ... P N 1011504 Rev B 11 18 20 Notes ...

Page 21: ...m the nearest authorized service agency 2 Antunes reserves the right to make changes in design or add any improvements on any product The right is always reserved to modify equipment because of factors beyond our control and government regulations Changes to update equipment do not constitute a warranty charge 3 If shipment is damaged in transit the purchaser should make a claim directly upon the ...

Reviews: