Antunes JS-1000 International Owner’S Manual Download Page 5

P/N 1011512 Rev A 10/18

5

Installation

Unpacking

1. 

Remove unit and all packing materi-

als from shipping carton.

2. 

Open the large box. Remove all 

packing materials and protective 

coverings from the unit and parts.

NOTICE:

 If any parts are missing or 

damaged, contact Antunes 

Customer Service IMMEDI-

ATELY at +1-877-392-7856 (toll 

free).

3. 

Place the unit where it will be used.

4. 

Wash, rinse, and sanitize hose con-

nection manifold, the cup mounting 

platform, the steam nozzle, and the 

cup at the sink. Wipe all surfaces of 

the unit with a clean, sanitized towel.

NOTICE:

 Do NOT use a dripping wet 

cloth. Wring out before use.

5. 

Install the hose connection manifold 

by sliding its flanges under the mani

-

fold retainer (see Figure 1).

6. 

Connect the drain tube to the hose 

connection manifold (see Figure 1.)

7. 

Snap the cup mounting platform 

into the four rectangular holes in 

underside of the steamer housing as 

shown in Figure 2.

8. 

Insert the steam nozzle through 

the opening in the cup mounting 

platform and into the bottom of the 

hose connection manifold and twist it 

a half-turn.

9. 

The cup attaches to the cup mount-

ing platform by twisting it a quarter-

turn.

10. 

Connect the Water Pressure Regula-

tor to the cold water line.

11. 

Direct the drain hose to a drain. Al-

low a 2 inch gap between the drain 

hose and the drain. Do NOT allow 

the drain hose to be submerged.

Equipment Setup

When placing the unit into service, pay 

attention to the following guidelines.

 

y

Make sure power is off and the 

unit is at room temperature.

 

y

Do NOT block or cover any 

openings on the unit.

 

y

Do NOT immerse cord 

or plug in water.

 

y

Keep cord away from 

heated surfaces.

 

y

Do NOT allow cord to hang 

over edge of table or counter.

Cup mounting platform

Steam nozzle

Cup

Steamer housing

 

y

Place unit on a sturdy, level 

table or work surface.

 

y

Make sure there is at least a 3 inch 

gap between walls and the unit.

Do not connect to a circuit operating at 

more than 150 volts to ground.

 

y

Install the steamer with adequate 

backflow protection complying 

with all applicable codes.

Verify that the line voltage corresponds to 

the voltage on the unit specification label.  

Touchscreen

This unit is equipped with a touchscreen 

that uses a graphical user interface or 

GUI that acts as the main control for the 

unit.
Treat the GUI interface with the same 

care as you would any touchscreen 

device. Do not use tools or objects on the 

GUI. Do not scratch or damage the GUI.

Hose

connection

manifold

Manifold retainer

Drain tube

Figure 1. 

Installing the hose connection manifold

Figure 2. Components

Summary of Contents for JS-1000

Page 1: ...N 1011512 Rev A 10 18 Jet Steamer International Owner s Manual JS 1000 IPX3 Rating Manufacturing Number 9100672 Original Instructions www antunes com CAUTION Read the instructions before using the machine ...

Page 2: ...tact Antunes Customer Service immediately at 1 877 392 7856 toll free Fill in the information in the next section and have it ready when calling for assis tance The serial number is on the specifi cation sticker located on the system Equipment Information to Save Purchased from Date of purchase Model number Serial number Manufacturing number Authorized Service Agency Name Phone No Address Table of...

Page 3: ... is not to be used by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction y y Children being supervised are not to play with the appliance y y Bread may burn Therefore toasters must not be used near or below curtains or other combustible walls and materials Failure to maintain saf...

Page 4: ...odel A Width B Depth C Height 9100672 12 5 318mm 20 75 527mm 20 508mm Mfg No Volts Watts Amps Hertz Plug Description Plug Configuration 9100672 208 240 3800 19 60 HRMN IEC 309 P N 0700588 Assembly Only Electrical Ratings Specifications ...

Page 5: ...gula tor to the cold water line 11 Direct the drain hose to a drain Al low a 2 inch gap between the drain hose and the drain Do NOT allow the drain hose to be submerged Equipment Setup When placing the unit into service pay attention to the following guidelines y y Make sure power is off and the unit is at room temperature y y Do NOT block or cover any openings on the unit y y Do NOT immerse cord ...

Page 6: ...ontrolled by a normally closed solenoid valve located inside the steamer s electrical housing 1 Turn off the water valve not supplied that provides water to the unit 2 Connect the 1 4 6 5 mm ID flexible tubing to the outlet side of the water pressure regulator and secure using the worm clamp NOTICE A Water Pressure Regulator must be installed Failure to do so will result in poor steaming and possi...

Page 7: ...e If the food item you are cooking is already shown on the display you can simply press it 6 The unit begins the cooking cycle The display shows the time remain ing in the cooking cycle and beeps when cooking is complete 7 When cooking is complete the unit returns to the Ready screen 8 Remove the cup from the unit and continue with food preparation as required Power button Touchscreen display Figu...

Page 8: ...yed onto the steam generator y y Shot Rate The time between each shot of water onto the steam generator y y Shot Count This value is automatically calculated by the system using the Cycle Time and Shot Rate values This is the number of total shots of water that will occur during the cook cycle for that menu item The shot count can only be changed by adjusting the Cycle Time or Shot Rate values You...

Page 9: ... press the radio button next to each setting before you can adjust it 5 Once you have changed the System settings as desired press the Save icon The system saves the changes to memory To cancel your changes press the Cancel icon to return to the Tools screen Loading Menu Data via USB The steamer is equipped with a USB in terface on the side of the unit see Figure 4 This allows you to load menu ite...

Page 10: ...TICE You do not need to wait until the cool down mode completes However the unit will be hot so wear heat resistant gloves dur ing cleaning 3 Wearing heat resistant gloves remove the components highlighted in Figure 5 4 Wash rinse and sanitize those com ponents at the sink or in the dishwash er Allow them to air dry 5 Wipe the exterior of the unit with a clean sanitized towel Clean up any spills c...

Page 11: ...Knobs see Figure 6 This allows the Generator Mani fold to be opened 4 Use a flat blade screw driver to gently pry up the Generator Manifold and remove it 5 Inspect the Generator Manifold and Generator Figure 5 If mineral deposits have formed place a flat blade screwdriver into openings Use a twisting motion to scrape openings clean NOTICE If the mineral deposits come off in flakes or in layers bui...

Page 12: ...Authorized Service Agency for service Unit displays system error Database Failure Possible data corruption on the receipts Do a factory reset from the Menu Items menu to reset stored receipts Reenter any missing receipts Unit heats but little or no steam is produced and or the product requires more steaming than usual Water line valve is closed Verify that the water line valve is open Strainer is ...

Page 13: ...P N 1011512 Rev A 10 18 13 WIRING DIAGRAM ...

Page 14: ...cription Qty 42 0200379 Gasket 1 43 0507800 Gasket retainer 1 44 0400290 Electrical insulator 2 45 1002730 Wiring diagram label 1 46 0507960 Rear panel 1 47 3060130 Nut hex KEPS 06 32 steel zinc plated 2 48 0508575 Quick disconnect mount 1 49 2080117 Quick disconnect 1 8 NPT 1 50 4040145 Solenoid valve 24 VAC 1 51 2140159 Teflon tape 1 4 1 52 2190179 Elbow 1 8 NPT x 3 16 barb 1 53 0700588 Power co...

Page 15: ...ch Lever kit 7001636 Front Housing Micro Switch kit 7001637 PCB Assy Switch Board kit 7001638 Terminal Block kit 7001639 Control board kit 7001661 Cup 7001662 Steam nozzle 7001663 Cup mounting platform 7001664 Hose connection manifold 7001665 Cup and steam nozzle kit 7001666 Cup nozzle and cup mounting platform kit 7001667 Complete accessory kit 1 cup 1 steam nozzle 1 cup mounting platform 1 hose ...

Page 16: ... 9 8 12 11 10 15 26 25 27 53 54 48 55 59 60 63 66 65 64 14 69 70 67 73 72 58 57 56 71 74 75 76 77 78 68 18 19 21 24 23 22 7 20 17 50 49 51 52 13 28 29 30 31 32 33 34 35 39 36 38 37 40 79 80 81 47 81 83 82 82 21 61 62 47 42 43 47 46 45 44 41 7 ...

Page 17: ...P N 1011512 Rev A 10 18 17 Notes ...

Page 18: ...cover water con tamination problems such as foreign material in water lines or inside solenoid valves It does not cover water pressure problems or failures resulting from improper incorrect voltage supply This warranty does not cover Travel Time Mileage in excess of 2 hours 100 miles 160 km round trip from the nearest authorized service agency 2 Antunes reserves the right to make changes in design...

Reviews: