P/N 1011596 Rev. A 05/21
5
System Capacities
400 GPD System
600 GPD System
Minimum Operating Pressure
10 psi
10 psi
Maximum Operating Pressure
100 psi
100 psi
Minimum Operating Temperature
40° F (4° C)
40° F (4° C)
Maximum Operating Temperature
100°F (38° C)
100°F (38° C)
pH Range
4-10
4-10
Maximum Total Dissolved Solids
(TDS)
1,000 ppm
1,000 ppm
Maximum Hardness
60 gpg
60 gpg
Site Density Index
< 5
< 5
Iron, Hydrogen Sulfide, or
Manganese
0
0
Nominal Capacity
400
600
(Membrane
performance after 24
hours at 77° F (25° C),
500 ppm TDS, and 70
psig)
(Membrane
performance after 24
hours at 77° F (25° C),
500 ppm TDS, and 80
psig)
Performance Claims for Percent Reduction
Substance
Minimum % Reduction
Total Dissolved Solids (TDS)
94%
NOTE:
Do not use with water that is microbiologically unsafe or of unknown
quality without adequate disinfection before or after the system. Systems
certified for cyst reduction may be used on disinfected waters that may
contain filterable cysts.