UFL-420/440 WATER FILTRATION SYSTEM
7
P/N 1010873 Rev. C 05/05
PERFORMANCE DATA SHEET
Filter Cartridge Capacities
Maximum Operating Pressure
100 psig (690 kPa)
Maximum Operating Temp.
104°F (40°C)
Maximum Trans Membrane Pressure 45 PSI (3.1 Bar)
pH Range
3-10
MWCO
100 kD
System Capacities
Series
UFL-420
UFL-440
Liters per hour
1045
2089
Liters per minute
17
35
Gallons per hour
276
552
Gallons per minute
4.6
9.2
System Tested and Certified by NSF
International against NSF/ANSI
Standard 42 and 53 for the reduction of:
Standard No. 42: Aesthetic Effects
Nominal Particulate Reduction Class I
Standard No. 53: Health Effects
Cyst Reduction
Turbidity Reduction
This system has been tested according to NSF/ANSI
Standard 42 and 53 for reduction of the substances
listed below. The concentration of the indicated sub-
stances in water entering the system was reduced to a
concentration less than or equal to the permissible limit
for water leaving the system, as specified in NSF/ANSI
42 or 53. While testing was performed under standard
laboratory conditions, actual performance may vary.
Performance Claims for Percent Reduction
Substance
Influent
Challenge
Concentration
Reduction
Requirement
cyst
1
minimum 50,000/L
99.95%
Turbidity
11+/1 NTU
≤ 0.5 NTU
Particulate Class I
Particles 0.5 to <
1
µ
m
at least 10,000
particles /mL
85%
1based on the use of microspheres or
Cryptosporium parvum
oocysts