Installing the upper limit sensor
(Capacitive, adjustable)
The delivery of the dryer machinery includes a capacitive level guard with an adjustable rod.
Installation dimensions for the upper limit sensor are presented in the drawing below. Seal the joint between the
bracket and the cover using mastic glue. Install the sensor sufficiently low to prevent the elevator from congesting
during the first times of use. The correct height of the sensor is about 60 cm from the top.
Follow the dryer's filling rate during the first filling and drying rounds. You must search out the correct height for
the upper limit sensor, because in practice, it varies. Observe that the grain mass expands in the beginning of the
drying phase. Therefore, some space must be reserved for the pre-cleaner. Fix the height position of the sensor
using the wing screw.
Over time, the sensor's head may get dirty and start transmitting wrong data. Due to the above reason, the sensor
head should be cleaned from time to time.