background image

Antti-Teollisuus Oy 

408107 

09-2016

Optivol

Using the Optivol

This manual deals with the shutter to be installed inside the air duct in the drying section of a grain dryer. The 

intention of this product is to optimise the drying process of small batches. The correct ways to install and operate 

the unit are presented in this manual.

Read this manual carefully before starting the installation.

Safety

-  

The Optivol includes moving parts that can cause a fracture, if touched while the machine is running! 

Never open the inspection doors of the machine unless you have first ensured that the power supply 

circuit is disconnected, e.g., by removing the fuse!

-  The following warning sign is affixed to the Optivol:

IMPORTANT! 

-   The instructions in the text must be followed; otherwise the Optivol and/or the other accessories may get dam-

aged. This may also result in faulty operation or reduced capacity.

Warning!

-   Always use protective gloves when installing or handling the Optivol.

Warning!

-  Switch off the machine, and disconnect the power supply before carrying out any installation or main-

tenance work.

Warning!

-   Connecting the electric appliances must be assigned to a skilled electrician. Refer to the separate con-

necting instructions for more information.

Warning!

-   The machine must not be started unless its doors, joints and connections have been installed in such 

a manner that they can only be opened by using tools.

Never open the door while the machine is in 

running - risk of injury to hands and fingers!

Summary of Contents for Agrosec Optivol M11

Page 1: ...and operating instructions Agrosec Optivol M11 408107 en 09 2016 ANTTI TEOLLISUUS OY Koskentie 89 FI 25340 Kanunki Salo Tel 358 2 774 4700 Fax 358 2 774 4777 E mail antti antti teollisuus fi www antti teollisuus fi ...

Page 2: ... Assembling the Optivol 5 Installing the Optivol inside the drying section 6 Installing the Optivol limit sensor inside the drying section 8 Wiring of the Optivol 9 SERVICING 9 GUARANTEE 9 EU Declaration of Conformity 11 CONTENTS ...

Page 3: ... fuse The following warning sign is affixed to the Optivol IMPORTANT The instructions in the text must be followed otherwise the Optivol and or the other accessories may get dam aged This may also result in faulty operation or reduced capacity Warning Always use protective gloves when installing or handling the Optivol Warning Switch off the machine and disconnect the power supply before carrying ...

Page 4: ...Antti Teollisuus Oy 4 408107 09 2016 Optivol ...

Page 5: ...Antti Teollisuus Oy 5 408107 09 2016 Optivol Assembling the Optivol Kuljetuspakkaus A73011P ...

Page 6: ...it and the drying section NOTE In the StandAlone models do not install the unit until the insulation work has been completed TIGHTEN THE CLAMP AS SOON AS THE SLUICE DOORS OF THE AIR DUCT ARE PARALLEL TO EACH OTHER NOTE SLUICE DOOR OF THE AIR DUCT AND THE LE VER PARALLEL TO EACH OTHER NOTE PARALLEL TO EACH OTHER NUMBER 1 SLUICE DOORS OF THE AIR DUCT CLOSED DIRECTION OF THE AIR FLOW ...

Page 7: ...ng force 1 Remove the cover of the motor fan 2 Rotate the motor until the lever reaches its vertical position as shown in the drawing Then set the sluice door parallel to the lever 3 Set now all the sluice doors in the closed position and turn the levers parallel to each other as shown in the drawing 4 Tighten the exhaust pipe clamps 5 Rotate the operating wheel back to its vertical position NUMBE...

Page 8: ... The installation plate for the sensor shall be attached to the end plate using self drilling screws Using external exhaust pipe clamps position the Optivol in the air duct shafts Place the clamps on either side of the Optivol centered with the clamps on the leverage Put first in place the clamp on the drying section side and after that put the cover in place and fasten the outer clamp NOTE In the...

Page 9: ...r is lubed for life and maintenance free GUARANTEE The guarantee period for the Optivol runs for one 1 operating season The guarantee covers defects in material and workmanship For the electric motors the guarantee terms issued by the importers manufacturers apply A prerequisite for validity of the guarantee is that the instructions issued by the manufacturer and the valid regula tions have been f...

Page 10: ...Antti Teollisuus Oy 10 408107 09 2016 Optivol ...

Page 11: ...UNKI Tel 358 0 2 7744700 Fax 358 0 2 7744777 declares that OPTIVOL CLOSING DEVICE FOR AIR DUCT conform with the provisions of the following directives Machine Directive 2006 42 EC Low Voltage Directive 2006 95 EC Electro Magnetic Compatibility Directive EMC 2004 108 EC Kuusjoki 05 05 2011 Kalle Isotalo Managing Director ...

Reviews: