Operation Features
• The XLR4 output converts AC to DC power when charging or can be used to deliver battery power to devices that only have an XLR input.
• Use the XLR4 output at the same time as charging.
• Supplied with a 4 Pin XLR Cable (Length ~10 ft. / 3 meters).
•
Supplied with AC Power Cable.
LED Status
Meaning
OFF
Charger is turned on with no batteries connected
Green
Charger is turned on with no batteries connected
Battery is fully charged or battery capacity is above 95%
RED
Battery connected with low or no power
Battery is Charging
Flashing RED and GREEN
Charger has detected a problem with the battery or charger. Contact Anton Bauer service center
Battery Capacity
Single Battery
Dual Battery
Charging order
45Wh
2 Hours
2 Hours
Simultaneous
90Wh
3.5 Hours
3.5 Hours
Simultaneous
150Wh
4.5 Hours
4.5 Hours
Simultaneous
240Wh
7 Hours
7 Hours
Simultaneous
The charger outputs 2.5A per channel. Regardless if 1 or 2 batteries are connected the charger will always provide each battery with 2.5 A .