HYDRAULIC CALLIPER TYPE NHCD-1400
Instructions for assembly, adjustment and maintenance
T.D.S.: BC.TDS.00025I
Rev.0.: September - 2012
When the sensor emits a warning, the operator must know that the following may
occur:
-
The brake is open, with which oil has entered into the hydraulic feed system at
the pressure shown in the attached table in point 1.3. of the instructions.
-
Depending on how the output cable of the sensor is connected (NC or NO), one
can also know if there is any problem with the wiring connections.
4.2.2. Lining wear sensor (D.D.)
(Optional in the assembly of the brake)
:
This sensor
detects the time at which the lining has been worn by 1 mm.
The sensor is the one as the one used to detect wear with the same technical
features.
How is the lining wear sensor adjusted?
The sensor (marked 36), continuously detects the strip (marked 8), which moves
together with the piston (marked 2) previously mention in the instructions, both with the
brake open as well as with the brake closed.
8
36