6
5
6
5)
fuse 250V/3,15A
6)
Fluid level
Fig. 2
Installation
Installing the Fogger
Remove all packing materials from the fog machine. Check that all foam and plastic padding is removed,
especially in the nozzle area.
Fill with Fog Liquid (ordercode 60603) or other high-quality water-based fog fluid. Any other types of fluid
can damage the unit. When filled, place cap back on liquid tank.
The unit can also be operated at floor level or sitting on any regular surface as well.
If the unit is to be mounted using the bracket, it is important that the fog does not shoot directly at any one’s
face. Therefore, do not point the nozzle in a direction that will aim directly at a person.
Whatever installation method you choose, do not allow the unit to have more than a 15 degree angle of
inclination.
Always disconnect from electric mains power supply before cleaning or servicing.
Damages caused by non-observance are not subject to warranty.
Set Up and Operation
Before plugging the unit in, always make sure that the power supply matches the product specification
voltage. Do not attempt to operate a 120V specification product on 230V power, or vice versa.
Procedure :
1.
Plug power cord into a grounded electrical outlet.
Warm-up is complete when lamp lights up on remote unit..
2.
To emit fog, press the button on the remote and hold
for the desired length of time.
3.
The remote unit’s lamp will cycle on and off as
the machine re-heats to the proper operating temperature.
Fig. 3