background image

3

 

Only use the high-quality, water-based fog liquid, that your Antari dealer recommends.(5L fogger
fluid ordercode 60603) Other fog liquids may cause poor effect fog, clogging and “spitting” of
unevaporated liquid.

 

Avoid flames and do not put close to flammable liquids or gases.

 

Always make sure there is sufficient liquid in the fog liquid tank.  Operating this unit without liquid will
cause damage to the pump and the heater.

 

Always allow free air space of at least 20 cm around the sides and top of the unit.

 

Always drain tank before shipping or otherwise transporting this unit.

 

Always keep tank cap closed while operating.

 

Always keep the fog machine upright.

 

For adult use only.  Fog machine must be installed out of the reach of children.  Never leave the unit
running unattended.   Leave the grid guarding the nozzle in place if the machine is to be used in the
presence of children

 

Always keep the nozzle at least 50 cm away from contact with anything, while in operation.

 

Always disconnect power from the mains, when device is not used or before cleaning! Only handle
the power-cord by the plug. Never pull out the plug by tugging the power-cord.

 

Make sure that the available voltage is not higher than stated on the rear panel.

 

Make sure that the power-cord is never crimped or damaged. Check the device and the power-cord
from time to time.

 

If device is dropped or struck, disconnect mains power supply immediately. Have a qualified
engineer inspect for safety before operating.

 

If the device has been exposed to drastic temperature fluctuation (e.g. after transportation), do not
switch it on immediately. The arising condensation water might damage your device. Leave the
device switched off until it has reached room temperature.

 

If your Antari Fog Machine fails to work properly, discontinue use immediately.  Drain all fog liquid
from the tank, pack the unit securely (preferably in the original packing material), and return it to your
Antari dealer for service.

 

Allow time to cool down, before cleaning or servicing.

 

The residence time of persons in smoke-filled rooms with less than 15 m of sight must never exceed
5 minutes.

 

The fog vapour at point of release is under pressure and is extremely hot.

 

The output nozzle becomes very hot during operation (300 degrees C).  Keep flammable materials
at least 50 cm away from the nozzle.

 

The use of smoke-fluid is only allowed for adults.

 

Repairs, servicing and electric connection must be carried out by a qualified technician.

 

In dense, smoke-saturated surroundings, the oxygen portion is substantially reduced!

 

The smoke density must be portioned in a way that the sight will always be above 5 m - Danger of
anxiety state due to missing orientation!

 

Every smoke-filled room must be overseen by a skilled person.

 

WARRANTY: Till one year after date of purchase.

Operating instructions:

This device is not designed for permanent operation. Consistent operation breaks will ensure that the device
will serve you for a long time without defects.

If this device is operated in any other way, than the one described in this manual, the product may suffer
damages and the

 

warranty becomes void.

Any other operation may lead to dangers like short-circuit, burns, electric shock, explosion, crash etc.
You endanger your own safety and the safety of others!

Summary of Contents for Z-80

Page 1: ...Antari Z 80 ORDERCODE 60651 ...

Page 2: ... rely on Antari for more excellent products We design and manufacture professional equipment for the entertainment industry New products are being launched regularly We work hard to keep you our customer satisfied You can get some of the best quality best priced products on the market from Antari So next time turn to Antari for more great equipment Always get the best with Antari Thank you ...

Page 3: ...roduct Guide Warning Safety instructions Operating Determinations Description Features Overview Installation Installing the fogger Set Up and Operation Procedure Remote control operation Maintenance Performance notes Troubleshooting Product Specifications ...

Page 4: ...contact with other cables Handle the power cord and all connections with the mains with particular caution Never remove warning or informative labels from the unit Never aim the output nozzle directly at people Never aim the output nozzle at open flames Never add flammable liquids of any kind oil gas perfume to the fog liquid Never drink fog liquid If it is ingested call a doctor immediately If fo...

Page 5: ...tuation e g after transportation do not switch it on immediately The arising condensation water might damage your device Leave the device switched off until it has reached room temperature If your Antari Fog Machine fails to work properly discontinue use immediately Drain all fog liquid from the tank pack the unit securely preferably in the original packing material and return it to your Antari de...

Page 6: ...russing systems have to be used Use a clamp to mount the fogger with the mounting bracket to the trussing system The fogger must never be fixed swinging freely in the room The installation must always be secured with a safety attachment e g an appropriate safety net or safety cable When rigging derigging or servicing the fogger always make sure that the area below the installation place is blocked...

Page 7: ...tures The Z 80 fogger is a small versatile and yet powerful fogger from Antari 700 W Heater warm up time approx 4 min Fog output min 80m3 Overview 1 2 3 4 Fig 1 1 Hanging bracket 2 800 ml Liquid tank 3 Remote control 4 Nozzle output ...

Page 8: ...irection that will aim directly at a person Whatever installation method you choose do not allow the unit to have more than a 15 degree angle of inclination Always disconnect from electric mains power supply before cleaning or servicing Damages caused by non observance are not subject to warranty Set Up and Operation Before plugging the unit in always make sure that the power supply matches the pr...

Page 9: ...Notes All fog machines develop condensation around the output nozzle Because this may result in some moisture accumulation on the surface below the output nozzle consider this condensation when installing your unit Fog machines may sputter small amounts of fog occasionally during operation and for a minute or so after being turned off All fog machines have a recycling period after bursts of fog wh...

Page 10: ...er Voltage AC 230V 50Hz CE Power consumption 700W 230V Fuse 250V 3 15A Warm up time approx 4 min Output 80m3 min Tank capacity 0 8L Dimensions 333x160x130mm Weight 4 5 kg Design and product specifications are subject to change without prior notice ...

Reviews: