7
Setting the output duration for timer operation
- Press the button
FUNCTION
until the display indicates
「
Duration Set
」
. Use the buttons
UP
and
DOWN
to adjust the duration of the fog outputs in timer mode within the range
of 1 and 200 seconds.
Setting the fog output volume for timer operation
- Press the button
FUNCTION
until the display indicates
「
Timer Out
」
. Use the buttons
UP
and
DOWN
to adjust the fog output volume in timer mode within the range of 1 % and 100
%.
Setting the fog output volume for continuous operation
- Press the button
FUNCTION
until the display indicates
「
Volume Out
」
. Use the buttons
UP
and
DOWN
to adjust the fog output volume in continuous mode within the range of
1 % and 100 %.
- To set the unit to continuous fog output, select
「
NON STOP BURST
」
below a value of 1 % or above
a value of 100 %.
Setting the DMX512 address
Press the
FUNCTION
until the display indicates
「
DMX 512 Add
」
. Use the buttons
UP
and
DOWN
, to set the machine to the same address as on your DMX controller. Please refer
to the chapter DMX512 settings for more information on DMX operation.
Turning the heater on or off
Press the
FUNCTION
until the display indicates
「
Heater On
」
. Use the button
MANUAL
, to switch the heater on or off.