Antari S-100II User Manual Download Page 1

 

 

S-100II , S-200

 

Snow Machine User Manual

 

 

 

 

 
 
 
 
 
 
 
 
 
 
 

 

 

 

 

English

Français

Deutsch

   •   

   •   

   •   

中文   

 

©

 

2018 Antari Lighting and Effects Ltd.

Summary of Contents for S-100II

Page 1: ...1 S 100II S 200 Snow Machine User Manual English Fran ais Deutsch 2018 Antari Lighting and Effects Ltd...

Page 2: ......

Page 3: ...ne that the unit is installed at the rated voltage Always unplug your ANTARI Snow Machine before filling its tank Turn off or unplug when not in use This machine is not water or splash proof If moistu...

Page 4: ...operate the system has arrived intact If any equipment is missing contact your ANTARI dealer immediately The shipping carton should contain the following Items 1 Snow machine with power cable 2 SC 2 v...

Page 5: ...lity water based snow liquid Any other types of fluid can damage the unit When filled place cap back on liquid tank 5 Firmly attach the 4 pin connector on the remote control cable to the proper input...

Page 6: ...continue pushing the remote button as this may damage the unit Reurn the machine to your Antari dealer Operation 1 Plug the power cable into a grounded electrical outlet 2 Turn on the machine by pres...

Page 7: ...occupies 1 channel To ensure that the control signals are properly directed to each device they require addressing This is to be adjusted for every single device by changing the DIP switches as set o...

Page 8: ...he system with pure water and let it pump for at least 1or 2 minutes This step helps to ensure a longer life span of the motor and the nozzle 3 It is strongly recommended to regularly clean the dust r...

Page 9: ...5l 1 32gal Antari SL Snow Foam Fluid 30 mins at max output 5 C 40 C 41 F 104 F DMX512 Manual 1 channel IEC Power XLR 3 pin DMX L505 W276 H310 mm L19 88 W10 87 H12 20 inch 11 kg 24 25 lbs S 200 US mode...

Page 10: ...de votre machine neige veuillez lire attentivement les instructions suivantes concernant le maniement la s curit et l entretien Instructions de s curit Prot ger de l humidit L appareil a t con u pour...

Page 11: ...e l appareil Ne jamais entrem ler des liquides enflammables composants gazeux ou huileux au liquide neige Veuillez suivre toute instruction de s curit appliqu e sur le bo tier de votre Machine Neige d...

Page 12: ...d avoir enlev toute la mousse et le rembourrage en plastique s rtout au bec de sortie de la machine 2 Placez la machine neige sur une surface plane et assemblez le r servoir comme indiqu ci dessous 3...

Page 13: ...condes v rifiez si le liquide passe par le disperseur qui est attach au r servoir Si vous n arrivez pas d terminer la cause du probl me ne continuez pas pressez le bouton de la t l commande Cela pourr...

Page 14: ...bit augmente avec un valeur accroissante Avec le valeur 255 la machine fonctionne avec un debit maximal Protocole DMX Data Fonction 0 5 Arr t 6 255 Marche c Adressage Pour que les signals de commande...

Page 15: ...on de ne pas polluer le liquide neige Apr s avoir rempli de liquide neige refermez toujours imm diatement les couvercles du bidon de liquide et du r servoir de la machine 2 Utiliser l eau d still pour...

Page 16: ...60 ml min 5l 1 32gal Antari SL Snow Foam Fluid 30 min d bit maximal 5 C 40 C 41 F 104 F DMX manuellement 1 canal CEI alimentation XLR 3 p les DMX L505 I276 H310 mm L19 88 I10 87 H12 20 inch 11 kg 24 2...

Page 17: ...herheitshinweise Vor N sse sch tzen Nur innerhalb geschlossener R ume betreiben Nicht f r den Betrieb im Freien geeignet Verwenden Sie bitte ausschlie lich 3 adrige geerdete Steckdosen Vor Inbetriebna...

Page 18: ...m ANTARI Schneeger t angebracht sind Verwenden Sie ausschlie lich die hochwertigen von Ihrem H ndler empfohlenen Schneefluids Achten Sie unbedingt darauf dass sich immer eine ausreichende Menge Fluid...

Page 19: ...das Ger t nicht an und versuchen Sie nicht es in Betrieb zu nehmen ohne vorher mit Ihrem ANTARI H ndler R cksprache gehalten zu haben Inbetriebnahme 1 Entfernen Sie alle Verpackungsmaterialien vom Ve...

Page 20: ...von sich gibt oder das Ausstr men von Schnee vollst ndig aufh rt trennen Sie das Ger t bitte sofort vom Netz Pr fen Sie dann das Fl ssigkeitsniveau die externe Sicherung die Verbindung mit der Fernbe...

Page 21: ...wird jedoch nicht beeinflusst Belegung der DMX Anschl sse Die Maschine verf gt ber 3 polige XLR Anschl sse f r den Anschluss an einen DMX Controller Die nachfolgende Grafik zeigt die Belegung der Buch...

Page 22: ...iert Werden mehrere Ger te auf eine Adresse definiert arbeiten sie synchron Belegung der DIP Schalter Enstellen der DMX Startadresse DIP Schalter Nr 1 2 3 4 5 6 7 8 9 Ger tenummer Kan le Startadresse...

Page 23: ...US model AC 100 120V 50 60Hz 7 5A EU model AC 220 240V 50 60Hz 3 8A 880W 160 ml min 5l 1 32gal Antari SL Snow Foam Fl ssigkeit 30 min bei max Aussto 5 C 40 C 41 F 104 F DMX512 manuell 1 Kanal IEC Stro...

Page 24: ...24 S 100II S 200 ANTARI Antari Antari...

Page 25: ...25 1 2 SC 2 3 4 5 1 2 3 M 8...

Page 26: ...26 4 Antari SL 5 SL 5A Antari 5 4Pin XLR 1 15 2 3 ON OFF Antari 1 2 3 S 200II S 200 DMX SC 2 4 SC 2 4 Pin XLR POWER...

Page 27: ...27 5 ON OFF IN USE 6 SC 2 OUTPUT VOLUME 10 100 DMX PIN 3 Pin XLR DMX Pin Pin 1 2 3 DMX a DMX DMX b DMX DMX 0 5 255 100 DMX DMX 0 5 OFF 6 255 ON c DMX DMX DMX...

Page 28: ...28 DMX 1 2 3 4 5 6 7 8 9 1 2 4 8 16 32 64 128 256 1 ON OFF 2 ON OFF 3 ON OFF 4 ON OFF 5 ON OFF DMX 1 2 1 2 3 ANTARI SL 5 SL 5A...

Page 29: ...SL 30 5 C 40 C 41 F 104 F DMX512 1 IEC XLR 3 pin DMX512 505 276 310 mm 19 88 10 87 12 20 inch 11 24 25 lbs S 200 AC 100 120V 50 60Hz 7 5A AC 220 240V 50 60Hz 3 8A 880 140 5 1 32 Antari SL 35 5 C 40 C...

Page 30: ......

Page 31: ......

Page 32: ...32 C08S20005...