Antaira Technologies - Industrial Ethernet Switches
LNX-2012G-SFP Series User Manual V1.0
50
V2c: Reserved for SNMPv2c.
Usm: User-based Security Model (USM).
Security
Level
Indicates the security model that this entry should belong to.
Possible security models are:
NoAuth, NoPriv: None authentication and none privacy.
Auth, NoPriv: Authentication and none privacy.
Auth, Priv: Authentication and privacy.
Read View
Name
The name of the MIB view defining the MIB objects for which
this request may request the current values. The allowed string
length is 1 to 32, and the allowed content is the ASCII
characters from 33 to 126.
Write View
Name
The name of the MIB view defining the MIB objects for which
this request may potentially SET new values. The allowed
string length is 1 to 32, and the allowed content is the ASCII
characters from 33 to 126.
5.8 Traffic Prioritization
The practice of implementing a process that when under heavy traffic pressure the network will
begin giving higher preference to traffic that has been assigned higher priority levels then other
traffic or non-assigned traffic.
5.8.1 Storm Control Configuration
There is a unicast storm rate control, multicast storm rate control, and a broadcast storm rate
control. These only affect flooded frames, i.e. frames with a (VLAN ID, DMAC) pair not present
on the MAC Address table.
The rate is 2^n, where n is equal to or less than 15, or "No Limit". The unit of the rate can be
either pps (packets per second) or kpps (kilopackets per second). The configuration indicates
the permitted packet rate for unicast, multicast, or broadcast traffic across the switch.
*Note:
Frames, which are sent to the CPU of the switch are always limited to approximately 4
kpps. For example, broadcasts in the management VLAN are limited to this rate. The
management VLAN is configured on the IP setup page.