Antaira Technologies - Industrial Ethernet Switches
LNX-1604G-SFP Series User Manual V1.1
15
7. Technical Specifications
Table 7.1 has the technical specifications for Antaira Technologies’ LNX-1604G-SFP series: 16-
port industrial gigabit unmanaged Ethernet switch with 12*10/100/1000Tx, and 4*100/1000 SFP
slots.
Standards
IEEE 802.3
10Base-T 10Mbit/s Ethernet
IEEE 802.3u
100Base-Tx, 100Base-Fx, Fast Ethernet
IEEE 802.3ab
1000Base-Tx Gigabit Ethernet
IEEE 802.3z
1000Base-X Gigabit Fiber
Switch
Property
Protocol
CSMA/CD
Data Process
Store and Forward
Flow Control
IEEE 802.3x flow control, back pressure flow control
Switch Architecture
Back
‐
Plane: Non
‐
Blocking Switching Fabric
Transfer Rate
14,880pps for 10Base-T Ethernet port
148,800pps for 100Base-TX Fast Ethernet port
1,488,000pps for Gigabit Ethernet port
Transmission Distance
Up to 100M (Fast Ethernet)
Transmission Speed
Up to 1000Mbps (Gigabit)
Memory Buffer
4Mbits
Jumbo Frame
12.2Kbytes
MAC Table Size
8K MAC Address
Port Interface
Ethernet (RJ45) Port
12*10/100/1000Tx, auto negotiation speed, full/half duplex mode, and
auto MDI/MDI-X connection
Fiber Port
4*100/1000 SFP Slots
Fiber Wavelength
Refer to SFP Modules
LED Indicator
Power 1, Power 2, Fault
Ethernet Ports: On
‐
Link/Flash
‐
data transmitting
SFP: Link/Active
Network Cable
10Tx: 2-pair UTP/STP Cat.3,4,5 cable EIA/TIA-568 100-ohm (100m)
100Tx: 2-pair UTP/STP Cat.5 cable EIA/TIA-568 100-ohm (100m)
1000Tx: UTP/STP Cat.5/5E cable EIA/TIA-568 100-ohm (100m)
Mechanical
Characteristics
Housing
Metal IP30 protection
Dimension
59 x 142 x 99 mm (W x H x D)
Weight
Unit Weight: 2.2 lbs. Shipping Weight: 2.7 lbs.
Mounting
DIN-Rail Mounting, wall-mounting (optional)
Power
Requirement
Input Voltage
12~48VDC Redundant Input
Power Connection
1 removable 6-contact terminal block
Overload Current Protection
Present – Slow Blown Fuse
Reverse Polarity Protection
Present
Power Consumption
16 Watts
Relay Contact
24 VDC, 1A resistive
Environmental
Limits
Operating Temperature
Standard: -10 to 70C (14 to 158F); EOT: -40 to 75C (-40 to 167F)
Operating Humidity
5% to 95% (Non-Condensing)
Storage Temperature
-40 to 85C (-40 ~ 185F)