Antaira Technologies - Industrial Ethernet Switches
LNP-0800G-M12-67-24 User Manual V1.0
5
2.4 LED Indicators
There are LED light indicators located on the front panel of the industrial Ethernet switch that
displays the power and network status. Each LED indicator has a different color and has its own
specific meaning, see below in
Table 2.1
.
LED
Color
Description
P1
Green
On
Power input 1 is active
Off
Power input 1 is inactive
P2
Green
On
Power input 2 is active
Off
Power input 2 is inactive
Fault
Red
On
There are three possible conditions that would make the
LED light up:
1. If the current PoE outputs of all connected PDs were
overloaded (>200 Watts)
2. If Power 1 or Power 2 was inactive
3. If the current PoE output of one or more PDs was
overloaded (>30Watts)
Off
Since the last reset of the fault LED, the PoE output of all
connected PDs has not over 200W and no PD has been
overloaded in this period and the power 1 & power 2 have not
failed
PoE Load
Off
Off
The current PoE output of all connected PDs
is ≤ 50%
Green
On
The current PoE output of all connected PDs is 51% ~ 70%
Blue
On
The current PoE output of all connected PDs is 71% ~ 90%
Red
On
The current PoE output of all connected PDs is 91% ~ 100%
Note
: The Max. PoE output of this switch is 200Watts.
Figure 2.3