Antaira Technologies - Industrial Ethernet Switches
LNP-0800G-M12-67-24 User Manual V1.0
6
Port G1 to G8
L/A
Green
On
Connected to the network with 1000Mbps
Flashing Networking is active
Off
Not connected to network
Amber
On
Connected to network with 10/100Mbps
Flashing
Networking is active
Off
Not connected to network
Port G1 to G8
PoE
Green
On
The current PoE output is enabled
Flashing Overload occurred (>30 Watts) at the connected PD
Off
The current PoE output is disabled
NOTE:
"P1/P2" is the abbreviation for "Power 1/Power 2",
and “L/A” is for Link/Activity”.
2.5 Grounding
Grounding and wire routing help limit the effects of noise due to electromagnetic interference
(EMI). Run the ground connection from the ground screw to the grounding surface prior to
connecting devices. The grounding screw symbol is shown blow in
Figure 2.4
.
Figure 2.4
Caution
: Using a shielded cable achieves better electromagnetic compatibility.
2.6 Ethernet Ports
M12 Interface (Auto MDI/MDIX)
◼
Connection Format: M12 8-Pin X-Coded Female Connector
◼
Transmission Rate: 10/100/1000 Mbit/s
Prepare the M12 8-Pin X-Coded Ethernet Port mating cable for Ethernet connection. The M12 X-
Coded Ethernet ports are auto-sensing for 10Base-T, 100Base-TX, or 1000Base-T devices
Table 2.1