Antaira Technologies - Industrial Ethernet Switches
LMP-2602G-SFP Series Hardware Manual V1.0
8
The following figures shows the 10,100 and 1000 Ethernet RJ-45 pin outs
2.7 Cabling
◼
Twisted-pair segments can be connected with an unshielded twisted pair (UTP) or shielded twisted pair
(STP) cable. The cable must comply with the IEEE 802.3ab 1000Base TX standard (e.g. Category 5,
5e, or 6, 6e). The cable between the equipment and the link partner (switch, hub, workstation, etc.)
must be less than 100 meters (328 ft.) long.
◼
Note: Cable size should be between 18~20 AWG and the torque should be tightened to 5lbs.
The small form-factor pluggable (SFP) is a compact optical transceiver used in optical communications
for both telecommunication and data communication applications.
◼
To connect the transceiver and LC cable, please follow the steps below:
First, insert the SFP transceiver module into the SFP slot as shown below in
Figure 2.5
. Notice that the
triangle mark is at the bottom of the SFP slot.
Figure 2.6
shows SFP transceiver module was inserted
.
Second, insert the fiber cable of the LC connector into the transceiver as shown below in
Figure 2.7.
Figure 2.7 - LC Connector to the Transceiver
Figure 2.5 - Transceiver to the SFP Module
Figure 2.6 - Transceiver Inserted