Antaira Technologies - Industrial Ethernet Switches
LMP-0800G Series Hardware Manual V1.2
10
3. After the DIN-Rail bracket is installed on the rear side of the switch, insert the top of the DIN-
Rail on to the track as shown below in Figure 3.2.
4. Lightly pull down the bracket on to the rail as shown below in Figure 3.3.
5. Check if the bracket is mounted tightly on the rail.
6. To remove the industrial Ethernet switch from the rail, do the opposite from the above steps.
3.2 Wall Mounting
Follow the steps below to mount the industrial Ethernet switch using the wall mounting bracket as
shown below in Figure 3.4.
Caution: “Wall” means industrial control panel wall
1. Remove the DIN-Rail bracket from the industrial Ethernet switch by loosening the screws.
2. Place the wall mounting brackets on the top and bottom of the industrial Ethernet switch.
3. Use the screws to screw the wall mounting bracket on the industrial Ethernet switch.
Caution: The torque for tightening the screws on the device is 3.5 in-lbs.
4. Use the hook holes at the corners of the wall mounting bracket to hang the industrial Ethernet
switch on the wall.
5. To remove the wall mount bracket, do the opposite from the steps above.
Figure 3.2
Insert the Switch on the DIN-Rail
Figure 3.3
Stable the Switch on DIN-Rail