2.7 Cabling
Use the four twisted-pair, category 5e, or the above cabling for the RJ45 port connections. The cable between the switch
and the link partner (switch, hub, workstation, etc.) must be less than 100 meters (328 ft.) in length.
Single-mode connector types have to use 9/125μm single-mode fiber cable, while multi-mode connector types have to use
62.5/125μm multi-mode fiber cable.
The fiber port of SC/ST type connector can work in multi-mode or single-mode. When connecting the fiber port to another
one, please follow Figure 2.4 to connect accordingly. Wrong connection will cause the port to work abnormally.
Figure 2.4 - SC Connector
Caution: This is a Class 1 / LED product that complies with IEC 60825-1. Do not stare into the Laser / LED beam.
Attention: Il s'agit d'un produit de classe 1 / LED conforme à la norme IEC 60825-1. Ne fixez pas le faisceau laser
/ LED.
2.8 Wiring the Power Inputs
Caution: Please follow the steps below when inserting the power wire.
Attention: Veuillez suivre les étapes ci-dessous lors de l'insertion du câble d'alimentation.
1. Insert the positive and negative wires into the PWR1 (V1+, V1-) and PWR2 (V2+, V2-) contacts on the terminal block
connector as shown below in Figure 2.5.