2.4 LED Indicators

There are LED light indicators located on the front panel of the industrial media converter that display the power status

and network status. Each LED indicator has a different color and has its own specific meaning, see below in Table 2.1.

LED

Color

Description

PWR

Green

On

Power Input 1 or 2 is active

Off

Power Input 1 and 2 are inactive

GFX L/A

Green

On

Connected to network at 1000Mbps

Flashing

Networking is active

Off

Not connected to network

LAN Port

(Upper LED)

Green

On

Connected to network, 1000Mbps

Flashing

Networking is active

Off

Not connected to network

LAN Port

(Lower LED)

Green

On

Connected to network, 10/100Mbps

Flashing

Networking is active

Off

Not connected to network

Table 2.1 - LED Indicators

Note: “PWR” is the abbreviation for “Power”, “GFX” is for “Gigabit Fixed Fiber port”, and “L/A” is for “Link/Activity”.

2.5 DIP Switch Setting

By default setting, DIP switch 1 and 2 is ON. There are 2 pins on the DIP switch on the front panel for setting the LFP (Link

Fault Pass) function, see Table 2.2 below for more details.

DIP Switch 1

DIP Switch 2

Function Description

ON

OFF

LFP function enable

OFF

OFF

LFP function disable

Table 2.2 - DIP Switch Settings

Caution: If changing the current DIP switch setting, the device should be powered off and then powered on

again to make the setting effective.

5

Summary of Contents for IMC-C1000 Series

Page 1: ...IMC C1000 XX Series Compact Industrial Gigabit Ethernet Media Converter with 10 100 1000Tx to 1000Fx SC ST Connector 12 48VDC Power Input Hardware Manual Version 1 2 May 2021...

Page 2: ...the product described in this manual without prior notice Antaira Technologies LLC will not be liable for any technical inaccuracies or typographical errors found in this guide Changes are periodicall...

Page 3: ...nterf rences nuisibles la r ception radio ou t l vision ce qui peut tre d termin en teignant puis en rallumant l quipement l utilisateur est encourag essayer de corriger les interf rences par une ou p...

Page 4: ...0 S4 T IMC C1000 S6 IMC C1000 S6 T IMC C1000 ST M IMC C1000 ST M T IMC C1000 ST S1 IMC C1000 ST S1 T IMC C1000 WA S1 IMC C1000 WA S1 T IMC C1000 WB S1 IMC C1000 WB S1 T This document is the current of...

Page 5: ...tion 3 2 1 Physical Dimensions 3 2 2 Front View Panel 4 2 3 Top View Panel 4 2 4 LED Indicators 5 2 5 DIP Switch Setting 5 2 6 Ethernet Ports 6 2 7 Cabling 7 2 8 Wiring the Power Inputs 7 2 9 Groundin...

Page 6: ...ion This product series supports DIN rail as well as wall mountable orientations and provides operating temperature range models in STD 10 C to 70 C and EOT 40 C to 80 C 1 1 Product Hardware Features...

Page 7: ...ispositif de protection sur l entr e d alimentation Les sp cifications mat rielles du convertisseur de m dia industriel les ports les informations de c blage et l installation du c blage seront d crit...

Page 8: ...a Converters IMC C1000 XX Series Hardware Manual v1 2 2 Hardware Description 2 1 Physical Dimensions Figure 2 1 below shows the physical dimensions of this product series W x D x H is 26mm x 95mm x 75...

Page 9: ...Figure 2 2 below shows the top panel of the product series Figure 2 2 Top View Panel 2 3 Top View Panel Figure 2 3 below shows the top panel of the IMC C1000 XX series media converter that is equipped...

Page 10: ...twork 1000Mbps Flashing Networking is active Off Not connected to network LAN Port Lower LED Green On Connected to network 10 100Mbps Flashing Networking is active Off Not connected to network Table 2...

Page 11: ...rossover Cable Straight Through Cable Pin Number Signal Pin Number Signal Pin Number Signal Pin Number Signal 1 RX 3 TX 1 RX 1 TX 2 RX 6 TX 2 RX 2 TX 3 TX 1 RX 3 TX 3 RX 6 TX 2 RX 6 TX 6 RX Table 2 2...

Page 12: ...e mode When connecting the fiber port to another one please follow Figure 2 4 to connect accordingly Wrong connection will cause the port to work abnormally Figure 2 4 SC Connector Caution This is a C...

Page 13: ...range between 18 20 AWG Attention Utilisez uniquement des conducteurs en cuivre 125 C serrez 5 lb Le calibre des fils du bornier doit tre compris entre 18 et 20 AWG 2 9 Grounding Note Grounding and w...

Page 14: ...Antaira Technologies Industrial Media Converters IMC C1000 XX Series Hardware Manual v1 2 Attention L utilisation d un c ble blind permet une meilleure compatibilit lectromagn tique 9...

Page 15: ...rear side of the industrial media converter Caution The torque for tightening the screws on the device is 3 5 in lbs Attention Le couple de serrage des vis sur l appareil est de 3 5 pouces livres 2 To...

Page 16: ...industriel 1 Remove the DIN Rail bracket from the industrial media converter by loosening the screws 2 Place the wall mounting brackets on the top and bottom of the industrial media converter 3 Use t...

Page 17: ...Industrial Media Converters IMC C1000 XX Series Hardware Manual v1 2 Figure 3 4 Remove DIN Rail bracket Below in Figure 3 5 are the dimensions of the wall mounting bracket Figure 3 5 Wall Mounting Br...

Page 18: ...ter please refer to the DIN Rail Mounting section for DIN Rail installation If it is required to wall mount the industrial media converter please refer to the Wall Mounting section for wall mounting i...

Page 19: ...dry soft cloth 4 3 Troubleshooting Always verify the right power cord or adapter is being used Never use a power supply or adapter with a non compliant DC output voltage or it will burn the equipment...

Page 20: ...ssure flow control Switch Properties Memory Buffer 1Mbit Jumbo Frame 10Kbytes MAC Table Size 8K Interface Ethernet Port 1 RJ45 Port w 10 100 1000T X Auto negotiation speed Full Half duplex mode and au...

Page 21: ...ent Relative Humidity 5 to 95 non condensing Regulatory Approvals EMI FCC Part 15 Subpart B Class A CE EN55032 EN61000 6 4 Class A EMS CE EN55024 EN61000 6 2 EN61000 4 2 3 4 5 6 8 Free Fall IEC60068 2...

Page 22: ...ntaira Technologies Industrial Media Converters IMC C1000 XX Series Hardware Manual v1 2 www antaira com tw info antaira com tw Any changes to this material will be announced on the Antaira website 17...

Reviews: