17
summary table of transmission setting; bandwidth and distance
extensibility tested for AWG 24 (0.5mm) twisted-pair without
noise and cross talk.
DIP-1
DIP-2
DIP-3
DIP-4
Mode
Channel
Band Plan SNR
OFF
CO
Interleave Symm
9db
ON (default) CPE
Fast
Asymm
6db
CO / CPE
n
◊ CO (Central Office) – the Master device mode, usually
the CO device will be located at the data center of ISP or
enterprise to link to the backbone.
◊ CPE (Customer Premises Equipment) – the Slave device
mode, usually the CPE device will be located at branch
office, home or remote side as the long reach data
receiver. The CPE can be connected to the PC, IP Camera
or Wireless Access Point and etc network devices.
Note
When the Ethernet Over VDSL2 Converter operate
at CPE mode, the DIP switch 2,3,4 is no function.
Fast and Interleave Mode
n
◊ Fast mode guarantees a minimum end to end latency less
than 1 ms.
◊ Interleaved mode provides impulse noises protection with
a duration less than 250 us. Interleaved mode has a
maximum end to end latency of 10m sec.
Band Plan
n
◊ User can switch the Band Plan either Symmetric or Asym-