xMove 2.0 Ultimate
5
5.2 Initial Parameter Set Up
TIP: PLEASE SET UP CORRECTLY IN THE “USER
SET“ MENU BEFORE YOU USE IT IN THE JOB FOR
THE FIRST TIME.
Press “ENTER/START“ key to the first screen on the left,
then press “MODE/ESC“ key to enter the parameter
setting menu.
You can switch at the same level menu by ◄ DEC/
INC ► key. Please refer the detailed flow chart on the
left.
When you are willing to alter the parameter value in the
program, press “ENTER/START“ key to make it blink,
then change the value with ◄ DEC/INC ► key. The
value will be stored by press “ENTER/START“ key once.
xMove 2.0 Ultimate can accept three types of Lithium
batteries: LiPo/LiIo/LiFe. YOU HAVE TO CHECK THE
BATTERY CAREFULLY AND SET IT UP CORRECTLY OR IT
WILL CAUSE A EXPLODE! (Please refer the table A)
xMove 2.0 Ultimate can recognise the cell count of
Lithium battery automatically at the beginning of
charge or discharge process to avoid from erroneous
setting by user. But deeply discharged battery can be
perceived incorrectly. To prevent the error, you can set
the time term to verify the cell count by the processor.
(see the screen )
Normally, 10 minutes are enough to perceive it
correctly. For the battery of larger capacity, you may
extend the time term. For the battery of smaller
capacity, you may reduce the term or use with the
default value.
A0