Digital Balance Charger xBase 2.0 Deluxe
5
When NiMH or NiCd battery is on the cyclic process of charge/
discharge, it can often become warm. The program insert a time
delay to occur after each charge and discharge process to allow the
battery adequate time to cool down before being subjected to the
next process (see the screen
A5
) the value ranges from 1 to 60
minutes. If you are not sure,you can set it over 10 minutes.
The charger will automatically supply the trickle function to achieve
the full charge with out overheating the battery after fast charge has
been teminated. You can alter the trickle value when the charger
shows you the screen
A6
.
When you start a charge process, the integral safety timer automati-
cally starts running at the same time. This is programmed to prevent
overcharge the battery if it proves to be faulty, or if the termination
circuit cannot detect the battery full
A7
. Shows you this program
can be on or off, and you can set the maximum safety time, the
value ranges from 10 to 720 min. As the same principle,there is a
maximum-capacity-limited function. See
A8
, the value ranges from
10 to 20000 mAh.
At the screen
A9
you can set the audible sounds to be on or off by
this program.
When you use the car battery to supply power for charger, screen
A10
shows you this program monitors the voltage of input DC battery.
If the voltage drops below the value you set the operation forcibly
terminated to protect the input battery.
You can adjust the brightness of LCD screen at the charger(see
A11
).
Please refer the information below
(chart A), and select the correct
parameter for each battery, or it will
cause a serious result!
Types
Item
Lipo
Lilo LiF
e NiMH NiCD Pb
Standard voltage (V/cell)
3.70
3.60
3.30
1.20
1.20
2.00
Max. charge voltage cut off level (V/cell)
4.20
4.10
3.60
1.60
1.60
2.45
Allowable fast current
<1C
<1C
<4C
<2C
<2C
<0.4C
Min. discharge voltage cut off level (V/cell)
>3.00
3.00
2.00
1.00
0.85
1.75
Chart A