You can inquire the temperature and ∆V continually by pressing the
“Dec. </INC >” key.
5.5 Pb battery program
5.5.1 Charging Pb battery
5.6 Save data and load data program
5.6.1 Save data
5.5.2 Discharging Pb battery
This is programmed for charging Pb batteries with nominal voltage
from 2 to 24 V. Pb batteries can not be charged rapidly. They can
only deliver relatively lower current compared to their capacity. The
optimal charge current will be 1/10 of the capacity. Please always
follow the instructions supplied by the manufacturer of battery.
As you can see on left, you can set up the charge current on the left.
The nominal of the second line and voltage of the battery on the right
of the second line. The charge current ranges from 0.1 - 10.0 A and
the voltage should be matched with the battery being charged.
Start the charge process by pressing the “Enter/Start” key for more
than 2 seconds.
The screen displays the state of charging process.
To stop charging forcibly, press “Mode/Esc” key once.
Set the discharge current on the left and final voltage on the right,
the discharge current ranges from 0.1 - 5.0 A and the voltage should
be matched with the battery being di charged. Start the discharge
process by pressing “Enter/Start” key for more than 2 seconds.
The screen displays the current state of discharge.
This charger can store/load up to 5 data of batteries, you can call out
the data for the process without setting up the program again.
Press “Mode/Esc.” key to the screen on the left, then press “Enter/
Start” key to enter into the submenu.
The blinking (01) shows you the data NO, you can press
“Dec. </INC >” key to change it. Press “Dec. </INC >” key, you can
select the type of battery, voltage, capacity, and you can set them by
pressing “Enter/Start” key, then press “Enter/Start” key for more
than 2 seconds to select the charge mode.
Setting up charge/discharge current and final voltage.
To save the data, press “Enter/Start” key for more Enter than 2
seconds.