background image

15

Ordering Information

Models 

MG3691B 

2 – 10 GHz Signal Generator

MG3692B 

2 – 20 GHz Signal Generator

MG3693B 

2 – 30 GHz Signal Generator

MG3694B 

2 – 40 GHz Signal Generator

MG3695B 

2 – 50 GHz Signal Generator

MG3696B  

2 – 67 GHz Signal Generator (operational to 70 GHz)

Options and Accessories

MG3690B/1A 

 Rack Mount with slides  – Rack mount kit containing a set of track 
slides (90 degree tilt capability), mounting ears, and front panel 
handles to let the instrument be mounted in a standard 19-inch 
equipment rack.

MG3690B/1B 

 Rack Mount without slides – Modifies rack mounting hardware  
to install unit in a console that has mounting shelves. Includes 
mounting ears and front panel handles.

MG3690B/2X 

 Mechanical Step Attenuator – Adds a 10 dB/step attenuator. Rated 
RF output power is reduced. (This option comes in different ver-
sions, based on instrument configuration.)

MG3690B/2E 

 Electronic Step Attenuator – Adds a 10 dB/step electronic attenuator 
with a 120 dB range for the MG3691B. Rated RF output power 
is reduced. (Not available with Option 20 or 22.)

MG3690B/3 

Ultra Low Phase Noise, main band – Adds new modules to  
significantly reduce SSB phase noise. (Not available with Option 30.)

MG3690B/4 

10 MHz to 2.2 GHz RF coverage, Ultra-Low Phase Noise 
version – Uses a digital down converter to significantly reduce 
SSB phase noise.

MG3690B/5 

10 MHz to 2 GHz RF coverage – Uses an analog down converter.

MG3690B/6 

Analog Sweep Capability – (limited to ≥500 MHz when used 

 

with Option 4.)

MG3690B/7 

IF Up-Conversion – Adds an internal 40 GHz mixer for up-converting 
an IF signal. (Not available with MG3695B, MG3696B, or  
with Options 18 or 20.)

MG3690B/8 

Power Monitor – Adds internal power measurement capability.  
(Not available with Option 9.)

MG3690B/9X 

 Rear Panel Output  – Moves the RF output connector to the rear 
panel. (This option comes in different versions, based on instrument 
configuration.) (Not available with Option 8.)

MG3690B/10 

 User-Defined Modulation Waveform Software – External software 
package provides the ability to download user-defined waveforms 
into the memory of the internal waveform generator, serially or via 
GPIB. External PC and an instrument with LF Generator, Option 27, 
are required.

MG3690B/12 

Frequency and Phase Modulation – External, via a rear panel BNC 
connector. For internal modulation capability, requires additionally 
LF Generator, Option 27.

MG3690B/14 

 Amplitude Modulation – External, via a rear panel BNC connector. 
For internal modulation capability, requires additionally  
LF Generator, Option 27.

MG3690B/15X 

 High Power – Adds high-power RF components to the instrument  
to increase its output power level. (This option comes in different 
versions, based on instrument configuration.)

MG3690B/16 

High Stability Time Base – Adds an ovenized, 10 MHz  
crystal oscillator as a high-stability time base.

MG3690B/17 

 Delete Front Panel – Deletes the front panel for use in remote  
control applications where a front panel display and keyboard 
control are not needed. (Only available with Options 1A or 1B)

MG3690B/18 

 mmW Bias Output – Adds a rear panel BNC Twinax connector 
required to bias the 63850 series millimeter wave source modules, 
sold separately. Includes DC bias cable. (Not available with  
Option 7 or 15x)

MG3690B/20 

 Scan Modulation – Adds an internal Scan modulator for  
simulating high-depth amplitude modulated signals. Requires an 
external modulating signal input capability. (Not available on models 
MG3693B, MG3694B, MG3695B, MG3696B, or with Options 2E,  
7, 15X, or 22.)

MG3690B/22 

 0.1 Hz to 10 MHz Audio coverage – Uses a DDS for coverage down 
to approximately DC. When adding Option 22, the output power is 
derated by 2 dB. The frequency resolution below 10 MHz is 0.02 Hz. 
No modulation is available in the 0.1 Hz to 10 MHz band.  
(Not available without Option 4 or 5, or with Option 20 or 2E)

MG3690B/26X 

 Pulse Modulation – External, via a rear panel BNC connector.  
For internal modulation capability, requires additionally Pulse  
Generator, Option 27. (This option comes in different versions, 
based on instrument configuration.)

MG3690B/27 

Internal LF and Pulse Generators – Provides modulation waveforms 
for internal AM, FM, FM, and Pulse. (Not available without  
Option 12, 14, or 26.)

MG3690B/28X* 

 Analog Modulation Suite – For ease of ordering and package  
pricing, this option bundles Options 12, 14, 26 and 27, offering  
internal and external AM, FM, FM, and Pulse Modulation.  
(This option comes in different versions, based on  
instrument configuration.)

MG3690B/30  

Low Phase Noise. (Not available with Option 3.)

MG3690B/37A 

Performance Suite – For ease of ordering and package pricing, this 
option bundles Options 2A, 5 and 28A, offering 10 MHz to 20 GHz 
frequency range, Step Attenuator and Analog Modulation Suite.

MG3690B/38A 

Ultra Performance Suite – For ease of ordering and package pricing, 
this option bundles Options 2A, 3, 4, 15A, 22 and 28A, offering  
0.1 Hz to 20 GHz frequency range, Step Attenuator, Ultra Low 
Phase Noise, High Power and Analog Modulation Suite.

MG3690B/39X 

CW Power Meter and Sensor Bundle – This bundle adds an 
ML2437A Power Meter with no options and an appropriate power 
sensor to the Synthesizer order.

 

Option 

Sensor 

 

Available with

 

39A   

MA2472D, 18 GHz 

MG3691B

 

39B   

MA2473D, 32 GHz 

MG3692B, MG3693B

 

39C   

MA2474D, 40 GHz 

MG3694B

 

39D   

MA2475D, 50 GHz 

MG3695B, MG3696B

MG3690B/40 

Pulse Power Meter and Sensor Bundle – This bundle adds an 
ML2495A Pulse Power Meter and MA2411B Pulse Power Sensor  
for models MG3691B, MG3692B, MG3693B, and MG3694B.

Summary of Contents for MG3690B

Page 1: ...age leveled output power spectral purity switching speed modulation performance size upgradeability reliability and service Our signal generators are configurable for a broad range of applications from R D to manufacturing and depot repair Anritsu provides you a total solution including proven reliability and standard 3 year warranty plus pre and post sale support that is the best in the industry ...

Page 2: ...nge of the instrument If the step size does not divide into the selected frequency range the last step is truncated Dwell Time Per Step Variable from 1 ms to 99 seconds Fixed Rate Sweep Allows the user to set the total time of the sweep including lock time Variable from 20 ms to 99 seconds Analog Sweep Mode Option 6 Sweep Width Independently selected from 1 MHz to full frequency range With Option ...

Page 3: ...438A and ML4803A and HP 437B 438A and 70100A Five user tables are avail able with up to 801 points table Warm Up Time From Standby 30 minutes From Cold Start 0 deg C 120 hours to achieve specified frequency stability with aging Instruments disconnected from AC line power for more than 72 hours require 30 days to return to specified frequency stability with aging Power 85 264 Vac 48 440 Hz 250 VA m...

Page 4: ...1 Hz to 10 MHz Option 22 30 dBc 10 MHz to 100 MHz Option 4 40 dBc 100 MHz to 2 2 GHz Option 4 50 dBc 10 MHz to 50 MHz Option 5 30 dBc 50 MHz to 2 GHz Option 5 40 dBc 2 GHz 2 2 GHz w Option 4 to 20 GHz 60 dBc 20 GHz to 40 GHz 40 dBc 40 GHz to 50 GHz MG3695B 40 dBc 40 GHz to 67 GHz MG3696B 25 dBc Frequency Range Standard 0 1 Hz to 10 MHz Option 22 30 dBc 10 MHz to 2 2 GHz Option 4 60 dBc 10 MHz to 2...

Page 5: ...6 GHz 54 60 77 86 104 108 108 113 107 112 130 136 6 GHz to 10 GHz 52 57 73 81 100 105 107 114 107 113 128 136 10 GHz to 20 GHz 45 49 68 76 94 100 102 108 102 107 125 135 20 GHz to 40 GHz 45 49 63 70 92 94 98 102 98 101 119 129 40 GHz to 67 GHz 37 40 57 69 86 88 92 96 90 95 113 123 Frequency Range Offset from Carrier 100 Hz 1 kHz 10 kHz 100 kHz 0 1 Hz to 10 MHz Option 22 90 110 120 125 130 139 130 ...

Page 6: ...able MG3693B w opt 4 or 5 STD STD STD 2 GHz 2 to 10 GHz 10 to 20 GHz 20 to 30 GHz 15 0 15 0 12 0 6 0 14 0 14 0 10 0 3 0 Not Available MG3694B w opt 4 or 5 STD STD STD 2 GHz 2 to 10 GHz 10 to 20 GHz 20 to 40 GHz 15 0 15 0 12 0 6 0 14 0 14 0 10 0 3 0 Not Available MG3695B w opt 4 or 5 STD STD 2 GHz 2 to 20 GHz 20 to 50 GHz 12 0 10 0 3 0 10 0 8 0 0 0 Not Available MG3696B w opt 4 or 5 STD STD 2 GHz 2...

Page 7: ...pt 4 or 5 w o opt 4 or 5 2 GHz 2 to 10 GHz 2 to 10 GHz 19 0 23 0 25 0 18 0 21 0 23 0 15 0 16 0 16 0 MG3692B w opt 4 or 5 w opt 4 or 5 w o opt 4 or 5 2 GHz 2 to 20 GHz 2 to 20 GHz 19 0 21 0 23 0 18 0 19 0 21 0 Not Available MG3693B w opt 4 or 5 w opt 4 or 5 w opt 4 or 5 w o opt 4 or 5 w o opt 4 or 5 2 GHz 2 to 20 GHz 20 to 30 GHz 2 to 20 GHz 20 to 30 GHz 17 0 21 0 17 0 23 0 19 0 16 0 19 0 15 0 21 0...

Page 8: ... signal range to an optimum value BNC connector rear panel External Power Meter Levels output power at a remote power meter location Accepts a 1V full scale input signal from the remote power meter L1 adjusts the input signal range to an optimum value BNC connector rear panel External Leveling Bandwidth 30 kHz typical in Detector mode 0 7 Hz typical in Power Meter mode User Level Flatness Correcti...

Page 9: ...8 MHz or 0 03 Fcarrier Unlocked Narrow DC to 10 MHz DC to Lesser of 10 MHz or 0 03 Fcarrier Unlocked Wide DC to 100 Hz DC to 100 Hz Flatness Locked Rate 10 kHz to 1 MHz 1 dB relative to 100 kHz Rate 10 kHz to Lesser of 1 MHz or 0 01 Fcarrier 1 dB relative to 100 kHz Accuracy Locked and Low noise Unlocked Narrow Rate 100 kHz sinewave Int or 1 Vpk Ext 10 5 typical Rate 100 kHz sinewave Int or 1 Vpk ...

Page 10: ...depth 10 kHz rate 0 2 radians typical External AM Input Log AM or Linear AM input rear panel BNC 50 Ω input impedance For internal modulation add LF Generator Option 27 Sensitivity Log AM Continuously variable from 0 dB per volt to 25 dB per volt Linear AM Continuously variable from 0 per volt to 100 per volt Maximum Input 1Vpk Pulse Modulation Option 26 Option 26 adds pulse modulation driven exte...

Page 11: ...dom waveforms one for amplitude modulation and the other for frequency or phase modulation The download files are simple space delimited text files containing inte ger numbers between 0 and 4095 where 0 corresponds to the minimum modulation level and 4095 the maximum In addition to the capability of downloading custom waveforms the software offers a virtual instrument modulation panel Custom modul...

Page 12: ...hich will be used only for purposes of displaying the proper frequency at the output of the mmW module on the MG3690B s front panel display MG3690B with 63850 Series Millimeter Wave Multiplier mmW Frequency Coverage 1 These mmW modules are produced by OML Inc Oleson Microwave Labs co located in Morgan Hill CA with mutual collaborative experiences over many years For detailed and up to date specifi...

Page 13: ... BNC Rear Panel 10 MHz REF OUT BNC Rear Panel HORIZ OUT BNC Rear Panel EFC IN BNC Rear Panel AUX I O 25 pin D type Rear Panel SERIAL I O RJ45 Rear Panel IEEE 488 GPIB Type 57 Rear Panel mmW BIAS Option 18 Twinax Rear Panel RF LO IF Option 7 K Connector female 3x Rear Panel PULSE TRIG IN Option 26 BNC Rear Panel PULSE SYNC OUT Option 27 BNC Rear Panel PULSE VIDEO OUT Option 27 BNC Rear Panel AM IN ...

Page 14: ...de an external lock loop Specifications on page 2 AUX I O Auxiliary Input Output Provides for most of the rear panel BNC connections through a single 25 pin D type connector Supports master slave operation with another synthesizer or allows for a single cable interface with the Model 56100A Scalar Network Analyzer and other Anritsu instruments see figure below SERIAL I O Serial Input Output Provid...

Page 15: ...his option comes in different versions based on instrument configuration MG3690B 16 High Stability Time Base Adds an ovenized 10 MHz crystal oscillator as a high stability time base MG3690B 17 Delete Front Panel Deletes the front panel for use in remote control applications where a front panel display and keyboard control are not needed Only available with Options 1A or 1B MG3690B 18 mmW Bias Outp...

Page 16: ...6 121 SMA male male flexible cable 90 cm 3 ft could be used to con nect the MG3690B output to the module s LO input Accessories 34RKNF50 DC to 20 GHz Ruggedized Type N female adapter for units with a K connector output ND36329 MASTER SLAVE interface cable set 63270 Transit case 16 kg 66 cm x 41 cm x 81 cm roll away on four wheels 2300 469 IVI Driver includes LabView driver 806 97 Aux I O Cable 25 ...

Page 17: ...formance Suite opt 2A 5 28A for MG3692B Opt 38A Ultra Performance Suite opt 2A 3 4 15A 22 28A for MG3692B Opt 39X CW Power Meter and Sensor Bundle Opt 40 Pulse Power Meter and Sensor Bundle Opt 98 Standard calibration to ISO 17025 and ANSI NCSL Z540 Opt 99 Premium calibration to ISO 17025 and ANSI NCSL Z540 Test report and uncertainty data included Footnote 1 Options 4 and 5 MAY NOT be ordered tog...

Page 18: ...18 ...

Page 19: ...19 ...

Page 20: ...one 358 20 741 8100 Fax 358 20 741 8111 Denmark Anritsu A S Kirkebjerg Allé 90 DK 2605 Brøndby Denmark Phone 45 72112200 Fax 45 72112210 Spain Anritsu EMEA Ltd Oficina de Representación en España Edificio Veganova Avda de la Vega no 1 edf 8 pl1 of 8 28108 ALCOBENDAS Madrid Spain Phone 34 914905761 Fax 34 914905762 Russia Anritsu EMEA Ltd Representation Office in Russia Tverskaya str 16 2 bld 1 7th...

Reviews: