Millimeter Wave Multipliers1 - 63850 series  

(Option 18 recommended for DC bias.)

63850 series external, waveguide output, multipliers are available for banded frequency 
coverage up to 325 GHz.

These external multipliers require at a minimum an MG3692B, with 20 GHz coverage. 
The output power required to drive the modules is +10 dBm. They can be powered up by 
an external power supply (+12Vdc, 1.5A typ.) using the supplied double banana power 
cord. It is recommended to purchase an MG3690B with option 18, which adds the capa-
bility to bias these modules without the need of an additional power supply. It adds a rear 
panel Twinax connector that supplies the proper DC bias for these modules, and a cable to 
power them up. Option 18 is not available with options 7 and 15.

63850 series multipliers have a saturated, unleveled, output power, yet their inherent 
flatness is exceptional. Modulating the input drive will indeed modulate the output, except 
for the case of Amplitude Modulation. Since the output is saturated, Amplitude Modulation 
is not recommended with these mmW modules. Frequency and Phase Modulation is 
possible, but the achieved deviation will be multiplied based on the multiplication factor of 
the module. Pulse modulation is also possible, with even sharper rise and fall times than 
the input. All modulation performances are not specified.

For ease of operation, the MG3690B allows the user to enter a frequency scaling factor, 
the module's multiplication factor, which will be used only for purposes of displaying the 
proper frequency at the output of the mmW module, on the MG3690B's front panel display.

MG3690B with 63850 Series Millimeter Wave Multiplier 

mmW Frequency Coverage

1  These mmW modules are produced by OML Inc. (Oleson Microwave Labs), co-located in Morgan Hill, CA., with mutual collaborative experiences over many years. 

For detailed and up-to-date specifications, please call OML, Inc. or visit their website at www.oml-mmw.com.

2 Waveguide output flanges are per MIL.F-3922/67B-(xxx)
3 Power rolls off from –15 dBm at 200 GHz, to –25 dBm typical at 220 GHz.
4 Output power is estimated.

Multiplier p/n

1

63850-15

63850-12

63850-10

63850-08

63850-06

63850-05

63850-03

Frequency

50-75 GHz

60-90 GHz

75-110 GHz

90-140 GHz

110-170 GHz

140-220 GHz

220-325 GHz

Waveguide Output

WR-15

WR-12

WR-10

WR-08

WR-06

WR-05

WR-03

Flange

2

(008)

(009)

(010)

(M08)

(M06)

(M05)

(M03)

Output Power  
(typical)

+8 dBm

+6 dBm

+5 dBm

–5 dBm

–13 dBm

–15 dBm

3

–25 dBm

4

Output Flatness  
(typical) (Unleveled)

±2 dB

±2 dB

±3 dB

––

––

––

––

Output Match

>12 dB

>12 dB

>12 dB

>12 dB

>12 dB

>12 dB

6 dB (typical)

Multiplication  
Factor (m)

x4

x6

x6

x8

x12

x12

x18

Input Frequency

12.5-18.75 GHz

10.0-15.0 GHz

12.5-18.4 GHz

11.2-17.5 GHz

9.1-14.2 GHz

11.6-18.4 GHz

12.2-18.1 GHz

Frequency Accuracy

(LO Synthesizer's Accuracy x m)

Frequency Resolution

(LO Synthesizer's Resolution x m)

Harmonics & Spurious

–15 dBc (typical)

Input Power Required

+10 dBm

RF Input Connector

SMA (female)

DC Power

12 Vdc, 1.5A (double banana power cord included) Option 18 is recommended on the synthesizer, to supply the necessary bias.

Dimensions

120 mm x 110 mm x 70 mm (not including feet or interfaces)

Weight

<1 kg

Temperature

+20 ºC to +30 ºC

Summary of Contents for MG3690B

Page 1: ...age leveled output power spectral purity switching speed modulation performance size upgradeability reliability and service Our signal generators are configurable for a broad range of applications from R D to manufacturing and depot repair Anritsu provides you a total solution including proven reliability and standard 3 year warranty plus pre and post sale support that is the best in the industry ...

Page 2: ...nge of the instrument If the step size does not divide into the selected frequency range the last step is truncated Dwell Time Per Step Variable from 1 ms to 99 seconds Fixed Rate Sweep Allows the user to set the total time of the sweep including lock time Variable from 20 ms to 99 seconds Analog Sweep Mode Option 6 Sweep Width Independently selected from 1 MHz to full frequency range With Option ...

Page 3: ...438A and ML4803A and HP 437B 438A and 70100A Five user tables are avail able with up to 801 points table Warm Up Time From Standby 30 minutes From Cold Start 0 deg C 120 hours to achieve specified frequency stability with aging Instruments disconnected from AC line power for more than 72 hours require 30 days to return to specified frequency stability with aging Power 85 264 Vac 48 440 Hz 250 VA m...

Page 4: ...1 Hz to 10 MHz Option 22 30 dBc 10 MHz to 100 MHz Option 4 40 dBc 100 MHz to 2 2 GHz Option 4 50 dBc 10 MHz to 50 MHz Option 5 30 dBc 50 MHz to 2 GHz Option 5 40 dBc 2 GHz 2 2 GHz w Option 4 to 20 GHz 60 dBc 20 GHz to 40 GHz 40 dBc 40 GHz to 50 GHz MG3695B 40 dBc 40 GHz to 67 GHz MG3696B 25 dBc Frequency Range Standard 0 1 Hz to 10 MHz Option 22 30 dBc 10 MHz to 2 2 GHz Option 4 60 dBc 10 MHz to 2...

Page 5: ...6 GHz 54 60 77 86 104 108 108 113 107 112 130 136 6 GHz to 10 GHz 52 57 73 81 100 105 107 114 107 113 128 136 10 GHz to 20 GHz 45 49 68 76 94 100 102 108 102 107 125 135 20 GHz to 40 GHz 45 49 63 70 92 94 98 102 98 101 119 129 40 GHz to 67 GHz 37 40 57 69 86 88 92 96 90 95 113 123 Frequency Range Offset from Carrier 100 Hz 1 kHz 10 kHz 100 kHz 0 1 Hz to 10 MHz Option 22 90 110 120 125 130 139 130 ...

Page 6: ...able MG3693B w opt 4 or 5 STD STD STD 2 GHz 2 to 10 GHz 10 to 20 GHz 20 to 30 GHz 15 0 15 0 12 0 6 0 14 0 14 0 10 0 3 0 Not Available MG3694B w opt 4 or 5 STD STD STD 2 GHz 2 to 10 GHz 10 to 20 GHz 20 to 40 GHz 15 0 15 0 12 0 6 0 14 0 14 0 10 0 3 0 Not Available MG3695B w opt 4 or 5 STD STD 2 GHz 2 to 20 GHz 20 to 50 GHz 12 0 10 0 3 0 10 0 8 0 0 0 Not Available MG3696B w opt 4 or 5 STD STD 2 GHz 2...

Page 7: ...pt 4 or 5 w o opt 4 or 5 2 GHz 2 to 10 GHz 2 to 10 GHz 19 0 23 0 25 0 18 0 21 0 23 0 15 0 16 0 16 0 MG3692B w opt 4 or 5 w opt 4 or 5 w o opt 4 or 5 2 GHz 2 to 20 GHz 2 to 20 GHz 19 0 21 0 23 0 18 0 19 0 21 0 Not Available MG3693B w opt 4 or 5 w opt 4 or 5 w opt 4 or 5 w o opt 4 or 5 w o opt 4 or 5 2 GHz 2 to 20 GHz 20 to 30 GHz 2 to 20 GHz 20 to 30 GHz 17 0 21 0 17 0 23 0 19 0 16 0 19 0 15 0 21 0...

Page 8: ... signal range to an optimum value BNC connector rear panel External Power Meter Levels output power at a remote power meter location Accepts a 1V full scale input signal from the remote power meter L1 adjusts the input signal range to an optimum value BNC connector rear panel External Leveling Bandwidth 30 kHz typical in Detector mode 0 7 Hz typical in Power Meter mode User Level Flatness Correcti...

Page 9: ...8 MHz or 0 03 Fcarrier Unlocked Narrow DC to 10 MHz DC to Lesser of 10 MHz or 0 03 Fcarrier Unlocked Wide DC to 100 Hz DC to 100 Hz Flatness Locked Rate 10 kHz to 1 MHz 1 dB relative to 100 kHz Rate 10 kHz to Lesser of 1 MHz or 0 01 Fcarrier 1 dB relative to 100 kHz Accuracy Locked and Low noise Unlocked Narrow Rate 100 kHz sinewave Int or 1 Vpk Ext 10 5 typical Rate 100 kHz sinewave Int or 1 Vpk ...

Page 10: ...depth 10 kHz rate 0 2 radians typical External AM Input Log AM or Linear AM input rear panel BNC 50 Ω input impedance For internal modulation add LF Generator Option 27 Sensitivity Log AM Continuously variable from 0 dB per volt to 25 dB per volt Linear AM Continuously variable from 0 per volt to 100 per volt Maximum Input 1Vpk Pulse Modulation Option 26 Option 26 adds pulse modulation driven exte...

Page 11: ...dom waveforms one for amplitude modulation and the other for frequency or phase modulation The download files are simple space delimited text files containing inte ger numbers between 0 and 4095 where 0 corresponds to the minimum modulation level and 4095 the maximum In addition to the capability of downloading custom waveforms the software offers a virtual instrument modulation panel Custom modul...

Page 12: ...hich will be used only for purposes of displaying the proper frequency at the output of the mmW module on the MG3690B s front panel display MG3690B with 63850 Series Millimeter Wave Multiplier mmW Frequency Coverage 1 These mmW modules are produced by OML Inc Oleson Microwave Labs co located in Morgan Hill CA with mutual collaborative experiences over many years For detailed and up to date specifi...

Page 13: ... BNC Rear Panel 10 MHz REF OUT BNC Rear Panel HORIZ OUT BNC Rear Panel EFC IN BNC Rear Panel AUX I O 25 pin D type Rear Panel SERIAL I O RJ45 Rear Panel IEEE 488 GPIB Type 57 Rear Panel mmW BIAS Option 18 Twinax Rear Panel RF LO IF Option 7 K Connector female 3x Rear Panel PULSE TRIG IN Option 26 BNC Rear Panel PULSE SYNC OUT Option 27 BNC Rear Panel PULSE VIDEO OUT Option 27 BNC Rear Panel AM IN ...

Page 14: ...de an external lock loop Specifications on page 2 AUX I O Auxiliary Input Output Provides for most of the rear panel BNC connections through a single 25 pin D type connector Supports master slave operation with another synthesizer or allows for a single cable interface with the Model 56100A Scalar Network Analyzer and other Anritsu instruments see figure below SERIAL I O Serial Input Output Provid...

Page 15: ...his option comes in different versions based on instrument configuration MG3690B 16 High Stability Time Base Adds an ovenized 10 MHz crystal oscillator as a high stability time base MG3690B 17 Delete Front Panel Deletes the front panel for use in remote control applications where a front panel display and keyboard control are not needed Only available with Options 1A or 1B MG3690B 18 mmW Bias Outp...

Page 16: ...6 121 SMA male male flexible cable 90 cm 3 ft could be used to con nect the MG3690B output to the module s LO input Accessories 34RKNF50 DC to 20 GHz Ruggedized Type N female adapter for units with a K connector output ND36329 MASTER SLAVE interface cable set 63270 Transit case 16 kg 66 cm x 41 cm x 81 cm roll away on four wheels 2300 469 IVI Driver includes LabView driver 806 97 Aux I O Cable 25 ...

Page 17: ...formance Suite opt 2A 5 28A for MG3692B Opt 38A Ultra Performance Suite opt 2A 3 4 15A 22 28A for MG3692B Opt 39X CW Power Meter and Sensor Bundle Opt 40 Pulse Power Meter and Sensor Bundle Opt 98 Standard calibration to ISO 17025 and ANSI NCSL Z540 Opt 99 Premium calibration to ISO 17025 and ANSI NCSL Z540 Test report and uncertainty data included Footnote 1 Options 4 and 5 MAY NOT be ordered tog...

Page 18: ...18 ...

Page 19: ...19 ...

Page 20: ...one 358 20 741 8100 Fax 358 20 741 8111 Denmark Anritsu A S Kirkebjerg Allé 90 DK 2605 Brøndby Denmark Phone 45 72112200 Fax 45 72112210 Spain Anritsu EMEA Ltd Oficina de Representación en España Edificio Veganova Avda de la Vega no 1 edf 8 pl1 of 8 28108 ALCOBENDAS Madrid Spain Phone 34 914905761 Fax 34 914905762 Russia Anritsu EMEA Ltd Representation Office in Russia Tverskaya str 16 2 bld 1 7th...

Reviews: