Path Analysis 

Signal Qualification 

 

Power meter 

 

Frequency meter 

Errors Analysis 

 

SONET/DSn 

A1/A2, B1, B2, REI-L, B3, REI-P, V5, REI-V, FAW (FAS), SFAW, FPS, MAW,  Parity P, 

Parity CP, F-bit, M-bit, FEBE, CRC-6, PRBS, Word, ERR

  

 

SDH/PDH 

A1/A2, B1, B2, MS-REI, B3, LP-B3, HP-REI, V5, LP-REI, FAW (FAS), CRC-4, REI (E-bit or 

REBE), PRBS, Word, ERR

 

Alarms Analysis 

 

SONET/DSn 

LOS, LOF, SEF, TIM-S, AIS-L, RDI-L, AIS-P, LOP-P, TIM-P, PLM-P, UNEQ-P, RDI-P, 
LOM-V, AIS-V, LOP-V, PLM-V, UNEQ-V, RDI-V, TIM-V, RFI-V, OOF, LSF, LOMF, RAI, 

IDLE, LSS, LPS, AIS

 

 

SDH/PDH 

LOS, LOF, OOF, RS-TIM, MS-AIS, MS-RDI, AU-AIS, AU-LOP, HP-PLM, HP-TIM,  
HP-UNEQ, HP-RDI, TU-LOM, TU-AIS, TU-LOP, LP-PLM, LP-UNEQ, LP-TIM, LP-RDI, 
LP-RFI, 

AIS, RDI, LOMF,

 LSS, LPS 

Pointer Movement Analysis 

 

Pointer value 

 

Number of positive and negative pointer movements 

 

Number of pointer movement with NDF 

Quality Analysis 

 

SONET 
Transmission quality is calculated each second as per GR-253 

 

SDH/PDH 
Transmission quality is calculated each second in accordance with recommendations G.826, 

G.828, M.2100, M2101.1, M.2101, M.2110 for performance 

 

Overhead Analysis 

 

J0, J1 and J2 Path Trace messages (ASCII sequence) 

 

S1 (synchronization status) 

 

C2/V5 (signal label) 

 

Complete display of SOH/TOH and POH of the analyzed path channel 

 

Capture capacity: 64 consecutive frames 

Event Analysis 

 

Alarms and errors event analysis in temporal graphical display with 125 µs resolution 

Round Trip Delay 

 

Measurement possible at each path level 

 

Resolution: 100 ns 

 

Range: 0 to 2 sec (depending on path level) 

 

Result: Maximum RTD, minimum RTD, Average RTD and errors/alarms detection 

Automatic Protection Switching Measurement 

 

Number of switches 

 

Switch duration (with 125 µs resolution) 

 

K1/K2 capture and interpretation 

Summary of Contents for CMA 5000 - UTA

Page 1: ...not always running smooth To this effect several important tests are always carried out in order to assess the good behaviour of these networks before turn up Similarly when the network has been turne...

Page 2: ...o Trouble scan APS RTD Concatenation Tandem Connection Monitoring ATM NGN monitoring NGN Monitoring option o Monitor several VCAT groups simultaneously o VCAT LCAS Differential Delay monitoring User p...

Page 3: ...ss involves switch actions between working fibers and backup fibers This process is completed when the equipments at both ends of the network have completed these actions within the same 50 ms complet...

Page 4: ...s its frame structure in a graph for fast and easy interpretation The Structure Scan graph can give a complete overview of the frame down to the tributary and allows the automatic configuration of the...

Page 5: ...pplication After stopping a measurement the report is just one click away produce save print reports directly from the application Select the set of results you want to produce fill in the header info...

Page 6: ...ith STM 4 16 64 155 52 MHz with STM 1 Data Communication Channel DB 15 connector D1 D3 192 Kb s channel D4 D12 576 Kb s channel Optical Interfaces 1 2 Ref Interfaces Wavelength Output Power Reach Over...

Page 7: ...ICMA5KUTASTM64 SPEC05 0806 A4 2008 Anritsu All Rights Reserved Page 7 of 14 DCC Signals The UTA SDH SONET application supports the drop and insert of DCC channels from SONET SDH D1 D3 192 Kb s D4 D12...

Page 8: ...Page 8 of 14 SDH Mappings Test Pattern PRBS Patterns PRBS 29 1 211 1 215 1 220 1 QRSS 223 1 229 1 231 1 inverted and non inverted Word Patterns All 1 pattern all 0 pattern alternative 01 pattern 1000...

Page 9: ...race Identifier o programmable 62 bytes ASCII sequence CRLF added or o programmable 15 bytes ASCII sequence CRC E 164 added or o programmable byte POH Editor VT V5 Z6 Z7 J2 Trace Identifier o programm...

Page 10: ...cordia GR 253 SDH Single Alternating Regular Double Regular Missing Double Alternating Periodic 87 3 Periodic 87 3 with Add Periodic 87 3 with Cancel SONET Single Burst of 3 Periodic Periodic with Add...

Page 11: ...Pointer value Number of positive and negative pointer movements Number of pointer movement with NDF Quality Analysis SONET Transmission quality is calculated each second as per GR 253 SDH PDH Transmis...

Page 12: ...rmance test result Automatic calculation of acceptance thresholds according to ITU T recommandations such as M 2100 M 2101 1 and M 2101 Automatic calculation of Performance Objectives according to ITU...

Page 13: ...10 Gig SDH SONET application SFP not included 5610 239 UTA Remote Command for SDH SONET application via Ethernet Remark Voice Add Drop ATM VCAT Monitoring options are not supported by remote commands...

Page 14: ...ark Phone 45 72112200 Fax 45 72112210 Spain Anritsu EMEA Ltd Oficina de Representaci n en Espa a Edificio Veganova Avda de la Vega n 1 edf 8 pl 1 of 8 28108 ALCOBENDAS Madrid Spain Phone 34 914905761...

Reviews: