background image

 

 

 

ISO 9001:2000 certified. ICMA5KUTASTM64-SPEC05-0806-A4. ©2008 Anritsu. All Rights Reserved.  

 

Page 10 of 14 

 

 

 

Alarm Addition 

SONET/DSn 

 

LOS, LOF, SEF, TIM-S, AIS-L, RDI-L, AIS-P, LOP-P, TIM-P, PLM-P, UNEQ-P, RDI-P, 
LOM-V, AIS-V, LOP-V, PLM-V, UNEQ-V, RDI-V, TIM-V, RFI-V, LOMF, LSF, OOF, RAI, 

IDLE, LSS, LPS, AIS 

SDH/PDH 

 

LOS, LOF, OOF, RS-TIM, MS-AIS, MS-RDI, AU-AIS, AU-LOP, HP-PLM, HP-TIM,  
HP-UNEQ, HP-RDI, TU-LOM, TU-AIS, TU-LOP, LP-PLM, LP-UNEQ, LP-TIM, LP-RDI, 
LP-RFI, 

AIS, RDI, LOMF,

 LSS, LPS 

Alarm Control 

 

On steady-state or programmable number of frames 

Voice Add/Drop (Option) 

SONET 

 

Supports adding and dropping of a selected 64/56 kb/s voice channel (carried in a DSn 

signal) to an external handset (µ-Law) 

SDH 

 

NA 

Stress Function 

Pointer Movement 

 

Pointer movement generation on SONET and SDH frames: 

o

 

Pointer set to any value with or without NDF 

o

 

Positive and negative movements 

o

 

Pointer sequences (ITU-T G.783, Telcordia GR-253) : 

SDH: 

 

Single Alternating 

 

R Double 

 

R Missing 

 

Double Alternating 

 

Periodic 87.3 

 

Periodic 87.3 with Add 

 

Periodic 87.3 with Cancel 

SONET: 

 

Single 

 

Burst of 3 

 

Periodic 

 

Periodic with Add 

 

Periodic with Cancel 

 

Periodic 87.3 

 

Periodic 87.3 with Add 

 

Periodic 87.3 with Cancel 

 

Phase Transient

 

Frequency Shift 

 

Programmable frequency offset: 

o

 

-100 ppm to +100 ppm in 0.1 ppm steps SONET/SDH 

APS (K1/K2) 

 

Automatic Protection Switch messages (K1/K2) are user-programmable 

 

MSP Linear (ITU-T G.783) and MSP-Ring (ITU-T G.841) are supported 

SDH Through Mode 

 

SOH overwrite: J0,  A1, A2, K1, K2, S1, M0, M1 

 

Error addition: A1A2, B1, B2, MS-REI, Transmission errors 

 

Alarm addition: LOS, LOF, OOF, MS-AIS, MS-RDI 

SONET Through Mode 

 

TOH overwrite:  J0, A1, A2, K1, K2, S1, M0, M1 

 

Error addition: A1A2, B1, B2, REI-L, Transmission errors 

 

Alarm addition: LOS, LOF, SEF, AIS-L, RDI-L

 

DS1 Loop Codes 

 

DS1 SF: Loop Up, Loop Down (CSU / NIU FAC1 / NIU FAC2) 

 

DS1 ESF: Line Loop Back Activate, Payload Loop Back Activate, Line Loop Back Deactivate, 

Payload Loop Back Deactivate, Universal Loop Back Deactivate (In-Band, Out-of-Band) 

Summary of Contents for CMA 5000 - UTA

Page 1: ...not always running smooth To this effect several important tests are always carried out in order to assess the good behaviour of these networks before turn up Similarly when the network has been turne...

Page 2: ...o Trouble scan APS RTD Concatenation Tandem Connection Monitoring ATM NGN monitoring NGN Monitoring option o Monitor several VCAT groups simultaneously o VCAT LCAS Differential Delay monitoring User p...

Page 3: ...ss involves switch actions between working fibers and backup fibers This process is completed when the equipments at both ends of the network have completed these actions within the same 50 ms complet...

Page 4: ...s its frame structure in a graph for fast and easy interpretation The Structure Scan graph can give a complete overview of the frame down to the tributary and allows the automatic configuration of the...

Page 5: ...pplication After stopping a measurement the report is just one click away produce save print reports directly from the application Select the set of results you want to produce fill in the header info...

Page 6: ...ith STM 4 16 64 155 52 MHz with STM 1 Data Communication Channel DB 15 connector D1 D3 192 Kb s channel D4 D12 576 Kb s channel Optical Interfaces 1 2 Ref Interfaces Wavelength Output Power Reach Over...

Page 7: ...ICMA5KUTASTM64 SPEC05 0806 A4 2008 Anritsu All Rights Reserved Page 7 of 14 DCC Signals The UTA SDH SONET application supports the drop and insert of DCC channels from SONET SDH D1 D3 192 Kb s D4 D12...

Page 8: ...Page 8 of 14 SDH Mappings Test Pattern PRBS Patterns PRBS 29 1 211 1 215 1 220 1 QRSS 223 1 229 1 231 1 inverted and non inverted Word Patterns All 1 pattern all 0 pattern alternative 01 pattern 1000...

Page 9: ...race Identifier o programmable 62 bytes ASCII sequence CRLF added or o programmable 15 bytes ASCII sequence CRC E 164 added or o programmable byte POH Editor VT V5 Z6 Z7 J2 Trace Identifier o programm...

Page 10: ...cordia GR 253 SDH Single Alternating Regular Double Regular Missing Double Alternating Periodic 87 3 Periodic 87 3 with Add Periodic 87 3 with Cancel SONET Single Burst of 3 Periodic Periodic with Add...

Page 11: ...Pointer value Number of positive and negative pointer movements Number of pointer movement with NDF Quality Analysis SONET Transmission quality is calculated each second as per GR 253 SDH PDH Transmis...

Page 12: ...rmance test result Automatic calculation of acceptance thresholds according to ITU T recommandations such as M 2100 M 2101 1 and M 2101 Automatic calculation of Performance Objectives according to ITU...

Page 13: ...10 Gig SDH SONET application SFP not included 5610 239 UTA Remote Command for SDH SONET application via Ethernet Remark Voice Add Drop ATM VCAT Monitoring options are not supported by remote commands...

Page 14: ...ark Phone 45 72112200 Fax 45 72112210 Spain Anritsu EMEA Ltd Oficina de Representaci n en Espa a Edificio Veganova Avda de la Vega n 1 edf 8 pl 1 of 8 28108 ALCOBENDAS Madrid Spain Phone 34 914905761...

Reviews: