background image

 

 

 

ISO 9001:2000 certified. ICMA5KUTASTM64-SPEC05-0806-A4. ©2008 Anritsu. All Rights Reserved.  

 

Page 1 of 14 

 

CMA 5000 - UTA    

SPECIFICATIONS 

 

Universal Transport Analysis Module / SDH/SONET Application 

 

 

 

 

Content 

 The perfect tool for testing SDH & SONET core networks up to 10 Gbps 

 Testing APS switch time reaction of the network with 125 µs resolution 

 Auto-discovery of the signal structure 

 Field exchangeable XFP and SFP 

 Fast and professional reports 

 

The perfect tool for testing SDH & SONET core networks up to 10 Gbps 

SDH and SONET technologies are firmly established in the core and metropolitan networks. STM-64 and OC-192 are widely 

deployed in today’s networks. While great care is devoted to warrant a very high quality of transport, in the real world of day-

to-day  installation,  commissioning  and  maintenance  activities  things  are  not  always  running  smooth.  To  this  effect,  several 

important tests are always carried out in order to assess the good behaviour of these networks before turn-up. Similarly, when 

the network has been turned on, it is paramount to keep monitoring the network health at physical level and beyond.  

 

The SDH/SONET application of the UTA module provides a complete set of test functions for testing SDH/SONET networks 

up to 10 Gbps, among which we find the checking & monitoring of the optical levels, alarm, error & frequency stressing, 

tributary mapping checking, routing, connectivity and pointer tests on the synchronous payloads, round trip delay measurement, 

BER tests, automatic protection scheme switching time and more.  

 

As a part of the UTA applications family, the SDH/SONET application is just one test solution among many others. The UTA 

module has been designed to support almost all the transport standards of modern networks (ex: 10 GigE, G.709, …) and 

represents a new class of tester for the field engineers. One tool is all you need! 

Summary of Contents for CMA 5000 - UTA

Page 1: ...not always running smooth To this effect several important tests are always carried out in order to assess the good behaviour of these networks before turn up Similarly when the network has been turne...

Page 2: ...o Trouble scan APS RTD Concatenation Tandem Connection Monitoring ATM NGN monitoring NGN Monitoring option o Monitor several VCAT groups simultaneously o VCAT LCAS Differential Delay monitoring User p...

Page 3: ...ss involves switch actions between working fibers and backup fibers This process is completed when the equipments at both ends of the network have completed these actions within the same 50 ms complet...

Page 4: ...s its frame structure in a graph for fast and easy interpretation The Structure Scan graph can give a complete overview of the frame down to the tributary and allows the automatic configuration of the...

Page 5: ...pplication After stopping a measurement the report is just one click away produce save print reports directly from the application Select the set of results you want to produce fill in the header info...

Page 6: ...ith STM 4 16 64 155 52 MHz with STM 1 Data Communication Channel DB 15 connector D1 D3 192 Kb s channel D4 D12 576 Kb s channel Optical Interfaces 1 2 Ref Interfaces Wavelength Output Power Reach Over...

Page 7: ...ICMA5KUTASTM64 SPEC05 0806 A4 2008 Anritsu All Rights Reserved Page 7 of 14 DCC Signals The UTA SDH SONET application supports the drop and insert of DCC channels from SONET SDH D1 D3 192 Kb s D4 D12...

Page 8: ...Page 8 of 14 SDH Mappings Test Pattern PRBS Patterns PRBS 29 1 211 1 215 1 220 1 QRSS 223 1 229 1 231 1 inverted and non inverted Word Patterns All 1 pattern all 0 pattern alternative 01 pattern 1000...

Page 9: ...race Identifier o programmable 62 bytes ASCII sequence CRLF added or o programmable 15 bytes ASCII sequence CRC E 164 added or o programmable byte POH Editor VT V5 Z6 Z7 J2 Trace Identifier o programm...

Page 10: ...cordia GR 253 SDH Single Alternating Regular Double Regular Missing Double Alternating Periodic 87 3 Periodic 87 3 with Add Periodic 87 3 with Cancel SONET Single Burst of 3 Periodic Periodic with Add...

Page 11: ...Pointer value Number of positive and negative pointer movements Number of pointer movement with NDF Quality Analysis SONET Transmission quality is calculated each second as per GR 253 SDH PDH Transmis...

Page 12: ...rmance test result Automatic calculation of acceptance thresholds according to ITU T recommandations such as M 2100 M 2101 1 and M 2101 Automatic calculation of Performance Objectives according to ITU...

Page 13: ...10 Gig SDH SONET application SFP not included 5610 239 UTA Remote Command for SDH SONET application via Ethernet Remark Voice Add Drop ATM VCAT Monitoring options are not supported by remote commands...

Page 14: ...ark Phone 45 72112200 Fax 45 72112210 Spain Anritsu EMEA Ltd Oficina de Representaci n en Espa a Edificio Veganova Avda de la Vega n 1 edf 8 pl 1 of 8 28108 ALCOBENDAS Madrid Spain Phone 34 914905761...

Reviews: