background image

ArcPad Zoom 48MC 

 

4.  ArcPad Zoom 48MC (RGBW) - DMX protocol 

Version 1.1  

 
Mode 1 

- Standard 16 bit, 

Mode 2 

- Reduced 8 bit 

Mode/Channel 

DMX 

Value 

Function 

Type of 

control 

 

0-29 

 
 
 
 

30-39 
40-49 
50-59 
60-69 
70-89 
90-99 

100-109 
110-179 

 
 

180-189 
190-255 

Special functions 

Reserved 

To activate following functions , stop in DMX value 
for at least 3 sec. and shutter  must be closed  at least 3 
sec. (Shutter channel 14/9 must be at range of 0-31 DMX). 
Corresponding menu items are temporily overrided. 

RGBW colour mixing mode 
CMY colour mixing mode 
Colour calibration mode On 
Colour calibration mode Off 
Reserved 
Dimmer curve: linear 
Dimmer curve: square law 
Reserved 

To activate zoom reset function, stop in DMX value for at 
least 3 sec. 

Zoom reset 
Reserved 

 
 

 
 
 
 

step 
step 
step 
step 

 

step 

step 

 
 
 

step 

 

0-255 

Red (Cyan) coarse  

Red LEDs saturation control (0-100%) 

 

proportional 

 

0-255 

Red (Cyan) fine  

Red LEDs saturation fine control min.—>max.

 

 

proportional 

 

0-255 

Green (Magenta)  coarse  

Green LEDs saturation control (0-100%) 

 

proportional 

 

0-255 

Green (Magenta) fine  

Green LEDs saturation fine control min.—>max.

 

 

proportional 

 

0-255 

Blue (Yellow) coarse  

Blue LEDs saturation control (0-100%) 

 

proportional 

 

0-255 

Blue (Yellow) fine  

Blue LEDs saturation fine control min.—>max.

 

 

proportional 

 

0-255 

White coarse (RGBW mode only)  

White LEDs saturation control (0-100%) 

 

proportional 

 

0-255 

White fine (RGBW mode only)   

White LEDs saturation fine control min.—>max.

 

 

proportional 

10 

 

1-255 

CT0   

No function 

Colour temperature correction  

 

step 

proportional 

11 

 

Virtual colour wheel

 

No function 

 
step 

Summary of Contents for ArcPad Zoom 48MC

Page 1: ...Version 1 1...

Page 2: ...rcPad Zoom 48MC RGBW DMX protocol 8 5 Control menu map RGBW version 10 6 Control menu 13 6 1 Addressing DMXA 13 6 2 Fixture information Info 13 6 3 Personality Pers 14 6 4 Manual Control Manual 14 6 5...

Page 3: ...f the type of power supplied consult your authorized distributor or local power company Always disconnect the fixture from AC power before cleaning removing or installing the fuses or any part Do not...

Page 4: ...ture becomes very hot during operation Allow the fixture to cool approximately 30 minutes prior to manipulate with it Operate the fixture only after having familiarized with its functions Do not permi...

Page 5: ...altering its operation characteristics The LED module can be tilted to desired position by means of the tilt lock Use an Allen key 6 to adjust desired tilt position Three slots in the mounting bracket...

Page 6: ...e with all national and local electrical and construction codes and regulations This device falls under class one and must be grounded The ArcPad Zoom 48 MC is equiped with with a 5 cored power data c...

Page 7: ...e 3 x 1 5mm2 You have to take into account the the length of power data cable circuit breaker etc at projecting of the fixtures installation 3 3 Wireless DMX operation The wireless version of the ArcP...

Page 8: ...nction stop in DMX value for at least 3 sec Zoom reset Reserved step step step step step step step 2 2 0 255 Red Cyan coarse Red LEDs saturation control 0 100 proportional 3 0 255 Red Cyan fine Red LE...

Page 9: ...nbow effect with fade time from min max speed Rainbow effect without fade time from min max speed step step step step step step step step proportional step proportional step proportional step proporti...

Page 10: ...l 6 Level 7 DMXA Set DMX address 001 255 DMX Pres Mode 1 Mode 2 Info POn Time Total Reset DMX In Powr 0 255 Dimm F 0 255 Temp Current High Res Highest Sw Ver IC 1 IC 2 IC 3 WL Pers DMX Pres Mode 1 Mod...

Page 11: ...evel 6 Level 7 C Mix M RGBW CMY Dimmer SqL Linear Temp Uni C F I Ef Pos Powr Dimm F Store Defaults Manual Powr Dimm F Test Prg Sta Alone Auto Run Off Test User Pr Play Test Prg User Prg Pr Edit Step 1...

Page 12: ...ArcPad Zoom 48MC 12 Level 1 Level 2 Level 3 Level 4 Level 5 Level 6 Level 7 Wireless Stat Unlink Adjust DMX Val Powr 0 255 Dimm F 0 255 Calib Red Green Blue Whit Store Load d C Sw Upd On Off...

Page 13: ...ntly from any other fixture on the DMX data link If there is no data received at the DMX input the display will start to flash 0001 with actually stored DMX address DMX Pres DMX preset Use the menu to...

Page 14: ...r turn it off two minutes after last pressing any button on the control panel Contrast Use this function to adjust contrast of the display 0 100 Backlight Use this function to adjust backlight of the...

Page 15: ...To edit program Procedure 1 Press UP or DOWN to select the menu Pr Edit and press ENTER 2 Press UP or DOWN to select the desired program step and press ENTER button 3 Press UP or DOWN to select the d...

Page 16: ...ram to the folder II Fixture software updating 1 Determine which of your ports is available on your PC and connect it with the DMX input of the fixture if you using the flash cable RS232 DMX with the...

Page 17: ...ted RDM controller to send commands to and receive messages from specific moving lights RDM allows explicit commands to be sent to a device and responses to be received from it The list of commands fo...

Page 18: ...els Operations modes DMX Stand alone Manual control of all effects via control panel One editable program up to 40 steps Wireless DMX RDM module only for ArcPad Zoom 48MC W Compliance with USITT DMX 5...

Page 19: ...rcPad Zoom 48MC 19 Temperatures Ambient temperature range 20 C 40 C Maximum housing temperature 70 C Total heat dissipation 440 BTU h calculated Weight 11 6 kg fixture 1 5 kg floor stand Dimensions mm...

Page 20: ...rcPad Zoom 48MC 20 Junction box Included items 1 x ArcPad Zoom 48MC 1 x Junction box P N 99714080 1 x Data power cable 1 x User manual Optional accessories Floor stand for ArcPad Zoom 48MC P N 1098023...

Page 21: ...aintenance and service operations are only to be carried out by a qualified person Should you need any spare parts please use genuine parts 9 1 Replacing a fuse This replacement has to be realized by...

Page 22: ...ArcPad Zoom 48MC 22...

Reviews: