Page 1: ...Version 4 0...

Page 2: ...e DMX protocols 10 4 1 RGBW version 1 0 10 4 2 SW version 1 0 12 4 3 SC version 1 0 13 5 Control menu maps 14 5 1 RGBW version Red Green Blue White 14 5 2 SW version Smart White 17 5 3 SC version Sing...

Page 3: ...from AC power before cleaning removing or installing the fuses or any part Do not overload wall outlets and extension cords as this can result in fire or electric shock Make sure that the power data c...

Page 4: ...tes prior to manipulate with it Operate the fixture only after having familiarized with its functions Do not permit operation by persons not qualified for operating the fixture Most damages are the re...

Page 5: ...each module separately by means of the self locking screws Danger of injury Two workers have to handle with the fixture including adjusting the LED modules to the desired position The LED modules are...

Page 6: ...e power supply and next 2 shielded cores are intended for DMX connection as shown the table Core Connection Core Connection Black Live Red Data Blue Neutral White Data Yellow Green Shielding 0 This de...

Page 7: ...ps for the second LED module of the fixture Never close the barn doors during fixture operation 3 4 Setting and control For setting DMX address selecting DMX mode and for another settings you need eit...

Page 8: ...put with the input of the next fixture until all fixtures are connected Do not overload the link Max 32 fixtures may be connected on a DMX link Caution Terminate the output of the last fixture with a...

Page 9: ...program start in the other slave fixtures All fixtures have a definite synchronized starting point when playing back their programs The number of running program is the same in all slaves and depends...

Page 10: ...Ds LED module 2 Red LEDs saturation control 0 100 proportional 6 6 0 255 Green LEDs LED module 2 Green LEDs saturation control 0 100 proportional 7 7 0 255 Blue LEDs LED module 2 Blue LEDs saturation...

Page 11: ...d Shutter open Strobe effect from slow to fast Shutter open Opening pulses in sequences slow fast Closing pulses in sequences fast slow Shutter open Random strobe effects from slow to fast Shutter ope...

Page 12: ...o control both LED modules 100 Warm white LEDs saturation cool white LEDs saturation 0 100 100 Cool white LEDs saturation warm white LEDs saturation 100 0 proportional proportional 3 5 0 31 32 63 64 9...

Page 13: ...4 255 Strobe both LED modules Shutter closed Shutter open Strobe effect from slow to fast Shutter open Opening pulses in sequences slow fast Closing pulses in sequences fast slow Shutter open Random s...

Page 14: ...Menu Level 2 Menu Level 3 Menu Level 4 Menu Level 5 Menu Level 6 A001 dM Ad 001 512 MA SL d AbL MASt SLA InFo Poti totL totL rSEt rSEt DM In rEd1 0 255 F dim 0 255 tEMP Cur t boAr LEdS Hi tE boAr LEd...

Page 15: ...u Level 5 Menu Level 6 tEM U C F bALA On Off C bAL rEd 0 200 255 GrEn 0 255 bLuE 0 237 255 Stor LOAd FuLL EcO In Po rEd1 0 255 F dim 0 255 Stor dFSE MAn M PrE C rEd1 rE1 1 rE1 3 dimr dim0 dim 7 Man C...

Page 16: ...6 Menu Level 1 Menu Level 2 Menu Level 3 Menu Level 4 Menu Level 5 Menu Level 6 PrG 3 Edit PrG 1 St 01 rEd1 0 255 PrG 3 St 68 S tim 0 25 5 sec CoPY SPEC rdML rdMH Adj DMH rEd1 F dimr CaL U rEd1 Wh4 St...

Page 17: ...Level 3 Menu Level 4 Menu Level 5 Menu Level 6 A001 dM Ad 001 512 MA SL d AbL MASt SLA InFo Poti totL totL rSEt rSEt DM In Uhi1 0 255 dinr 0 255 tEMP Cur t boAr LEdS Hi tE boAr LEdS rSEt boAr LEdS VEr...

Page 18: ...l 4 Menu Level 5 Menu Level 6 EcO In Po Uhi1 0 255 F din 0 255 Stor dFSE MAn M PrE C Uhi1 Uh0 1 Uh0 3 F dim dim0 dim 7 Man C Uhi1 0 255 F dim 0 255 TESt St AL Auto Off tESt PrG 1 PrG 3 PLAY tESt PrG 1...

Page 19: ...ArcPad Xtreme CE 19 Menu Level 1 Menu Level 2 Menu Level 3 Menu Level 4 Menu Level 5 Menu Level 6 SPEC rdML rdMH Adj DMH Uhi1 F dim CaL U Uhi1 Uhi4 Stor Hold On Off uPd...

Page 20: ...Level 3 Menu Level 4 Menu Level 5 Menu Level 6 A001 dM Ad 001 512 MA SL d AbL MASt SLA InFo Poti totL totL rSEt rSEt DM In rEd1 0 255 F dim 0 255 tEMP Cur t boAr LEdS Hi tE boAr LEdS rSEt boAr LEdS VE...

Page 21: ...nu Level 5 Menu Level 6 EcO In Po CoL 1 0 255 F dim 0 255 Stor dFSE MAn M PrE C CoL 1 Co1 1 Co1 3 dimr dim0 dim 7 Man C rEd1 0 255 F dim 0 255 TESt St AL Auto Off tESt PrG 1 PrG 3 PLAY tESt PrG 1 PrG...

Page 22: ...s ESCAPE button leaves menu without saving changes ENTER button enters menu confirms adjusted values and leaves menu UP and DOWN buttons move between menu items on the same level sets values Robe Univ...

Page 23: ...ArcPad Xtreme CE 23 The Remote LED Display window will appear Now you can fullly control the fixture using the UP Down Enter Escape and Reset buttons...

Page 24: ...ion about the fixture status To display desired information 1 Use the UP DOWN buttons to find the InFo menu 2 Press the ENTER button 3 Use the UP DOWN buttons to select the required menu item 4 Press...

Page 25: ...menu below I f this function is set off the will use maximum values 255 of saturation for red green and blue colour This function has to be set on before adjusting a white balance C bAL White Colour B...

Page 26: ...er List of control channels COL 1 LEDs saturation module 1 COL 2 LEDs saturation module 2 Stro a strobe shutter dimr a dimmer F dim a fine dimmer 4 Press the ENTER button and use the UP DOWN buttons t...

Page 27: ...and press the ENTER button 3 Use the UP DOWN buttons to select a program you want to edit PrG 1 PrG 3 and press ENTER button 4 Use the UP DOWN buttons to select a desired program step St 01 St 68 and...

Page 28: ...ry e g Anolis_Uploader on your hard disk and download the software into it 3 Unpack the program from the archive II Fixture software updating If you use the RDM Communicator 1 Disconnect the fixture f...

Page 29: ...mental Update box Avoid interrupting the process Update status is being displayed in the Info Box window When the update is finished the line with the text The fixture is successfully updated will app...

Page 30: ..._DEVICE DEVICE_MODEL_DESCRIPTION MANUFACTURER_LABEL DEVICE_LABEL SENSOR_DEFINITION SENSOR_VALUE DISPLAY_LEVEL DEVICE_RESET DMX_PERSONALITY DMX_PERSONALITY_DESCRIPTION STATUS_MESSAGES STATUS_ID_DESCRIP...

Page 31: ...djustable strobe sequences White colour balance adjusting RGBW version Lumen maintenance Channels full intensity Power mode L70 One LED channel Full mode Eco mode 95 000 108 000 Two LED channels Full...

Page 32: ...ArcPad Xtreme CE 32 Connection Power data cable junction box Rigging Via mounting bracket Temperatures Maximum ambient temperature 40 C Maximum housing temperature 85 C Dimensions mm ArcPad Xtreme...

Page 33: ...ction box Included items 1 x ArcPad Xtreme 1 x Junction box P N99012672 1 x User manual 1 x Gasket of cable grommet M20 PF P N 1305 1388 Optional accessories Barn doors in silver colour P N 10980081 T...

Page 34: ...sh or sponge and a mild non abrasive washing detergent Rinse it There are no serviceable parts inside the device Maintenance and service operations are only to be carried out by a qualified person Sho...

Page 35: ...the control unit The Chogori connectors are marked by self adhesive labels LED1 LED2 LED3 LED4 next to the connectors and the following order of cable connections has to be kept to ensure correct ope...

Page 36: ...be grounded in accordance with all national and local electrical and construction regulations In case that LED modules and the base are installed separately on the insulant e g wall LED modules and th...

Page 37: ...ArcPad Xtreme CE 37 Dimensions mm Weight LED module with mounting bracket 24 kg Control unit 9 kg Specifications are subject to change without notice December 2 2015...

Page 38: ...ArcPad Xtreme CE 38...