Animo WKT 5n HA User Manual Download Page 10

7.  MaINTENaNCE

 

• 

Clean the machine with a clean damp cloth.

• 

Avoid using abrasive. It can cause scratches and dim spots.

• 

Remove scale deposits by using scale remover. 

 

7.1  Descaling

During operation scale will develop in the machine. Therefore the machine needs to be descaled 

approx. once a month to guarantee the lowest energy consumption and proper functioning.

When to descale?

• 

Depending on the frequency of use and hardness of water used, we advise to inspect the

 

 

unit regularly for scale formation.

• 

Remove the cover of the storage water heater regularly. If there is loose scale on the bottom or  

 

if  there is severe scale formation on the walls, then the unit needs to be descaled.

• 

In some cases it is sufficient to only remove the loose scale.

1. 

Switch off the machine and remove the plug from the wall socket.

2. 

Remove the cover from the storage water heater.

3. 

Turn the machine upside down over the sink. The loose scale will come out.

4. 

If there isn’t any scale in the machine anymore, it taken into use again.

 

Consult section 5 “FIRST TIME USE”.

To remove remaining scale use ANIMO scale remover.

5. 

Carefully read the caution notice and the directions on the sachet ANIMO scale remover.

6. 

Dissolve 1 sachets of 50 gram ANIMO scale remover into 2 liters of warm water.

7. 

Fill the hot water reservoir with the solution. This will now undergo a reaction with the scale 

 

deposits.

8. 

Allow the solution to soak in for about 10 minutes until the frothing has stopped.

9. 

Tap some of the acid off and pour it back into the reservoir.

10.  Turn the machine upside down above the sink. Rinse the reservoir and the hot water tap, 

 

clean with hot water.

11.  If there is no scale left in the machine anymore, it taken into use again. Consult section

 

 

5 “FIRST TIME USE”.

 

WaRNING 

 

-  Stay near the machine while maintenance is being carried out.

-  When descaling, always follow the instructions of the scale remover used.

-  It is advisable to wear safety glasses and gloves during descaling.

-  Allow the machine to run through at least three times to rinse the solution from the system after 

 

it has been descaled. 

-  Wash your hands thoroughly after descaling

-  The appliance should not be submerged or hosed off.

-  Make sure all the repairs to the appliance are carried out by a qualified technician.

2015/02 Rev. 1.0

M-LINE

19

GB

Summary of Contents for WKT 5n HA

Page 1: ...WKT n 5 HA 5 VA gebruiksaanwijzing user manual betriebsanleitung mode d emploi...

Page 2: ...been written very carefully However Animo cannot be held responsible neither for mistakes in the book nor for their consequences Animo beh lt sich das Recht vor Einzelteile ohne vorherige Bekanntgabe...

Page 3: ...to the water supply system model VA 15 3 3 Connection to the electricity supply system 15 4 CONTROLS 16 5 FIRST TIME USE 17 6 NORMAL USE 18 6 1 The water heater in use model HA 18 6 2 The water heater...

Page 4: ...fitted which makes them for this purpose easy to operate The WKT 5n can be equipped with either manual filling HA or a fixed water connection VA for extra convenience In fig 1 the main parts are indi...

Page 5: ...y time after 4 ltr approx 11 min approx 11 min Electrical connection 1N 220 240 V 1N 220 240 V Frequency 50 60 Cy 50 60 Cy Power 2100 W 2100 W Weight empty 6 3 kg 6 6 kg Weight filled 11 3 kg 11 6 kg...

Page 6: ...as it can be dangerous if plugged in a socket The following points should be observed when wiring a new plug 1 The green yellow colored wire EARTH should be connected to the terminal which is either m...

Page 7: ...the correct temperature The control light turns off when the water temperature is too low Temperature adjuster water boiler fig 3C With this adjuster the water boiler temperature can be increased red...

Page 8: ...ter this the appliance is ready for use Model VA 1 Connect one side of the supported water supply hose between the swivel joint at the backside of the machine fig 1 10 and the other side to a manually...

Page 9: ...r boiler on using the on off switch fig 3D The light in the switch will light up The water in the water heater will now be heated up 2 After approx 14 minutes the water is heated up and the green temp...

Page 10: ...To remove remaining scale use ANIMO scale remover 5 Carefully read the caution notice and the directions on the sachet ANIMO scale remover 6 Dissolve 1 sachets of 50 gram ANIMO scale remover into 2 l...

Page 11: ...w appears replace its black cover and fasten it tightly If the protection was triggered due to scale formation then proceed according to section 7 1 When the scale formation was not the cause then ple...

Page 12: ...Animo B V Dr A F Philipsweg 47 P O Box 71 9400 AB Assen The Netherlands Tel 31 0 592 376376 Fax 31 0 592 341751 E mail info animo nl www animo eu 2015 02 Rev 1 0 1004224...