background image

50

06/2011 Rev. 7.4        

M o d e l   2 0 0 9

06/2011 Rev. 7.4

51

M o d e l   2 0 0 9

2. MENU 

STRUCTURE

2.1  The operator/service menu

The majority of settings, including product settings, are protected by a PIN code. This PIN code 
ensures that users do not gain access to the service menu.

It is recommended not to leave this document with the user after installation and to change the 
standard factory PIN code.

This section describes how the various settings can be changed by 

trained, authorized service staff.

 

You can read about how to gain access to the service menu below. On access to the 

service menu

 

the control panel has the following functions:

Summary:

      Display

Operator menu

Service menu

Make your choice

1.0

Free dispensing

2.1

Quick recipe Pro

1.1

Clock

2.2

Button settings

1.2

Timer settings

2.3

Recipe settings

1.3

Recipe counters

2.4

Settings

1.4

Quick recipe

2.5

Reset counters

1.6

Software

2.6

Descale /  lter

1.7

PIN-code

2.7

Hardware test

2.8

Read log

2.9

Clear log

2.10

Load defaults

2.11

SD menu

2.12

Change PIN code

2.2 The operator menu

Operator menu

Main item

Sub item

Item

Range

Set

Description

1.0 Free dispensing

Yes/no

Yes

Set the device to free or paid dispensing here.

1.1 Clock

Time

HH:MM

Set the clock to the correct local time here.

Date

DD-MM-JJJJ

Set the clock to the correct local time here.

1.2 Timer

Mon-Fri

On       00:00
Off       00:00  

Set the time when the device should operate here. If 
the timer switches off the device it will automatically 
revert to standby mode.

Sat

On       00:00
Off       00:00

Sun

On       00:00
Off       00:00

1.3 Recipe counters

Recipe  1

Recipe  10

Total

Off       00:00

Total counter for recipe 1 (free-paid-jugs)

Free

Cups

Number of free dispensed drinks (recipe 1)

Paid

Cups

Number of paid dispensed drinks (recipe 1)

Jug

Cups

Number of dispensed jugs (recipe 1)

Recipes total

Total

Cups

Total counter for all dispensed recipes

Free

Cups

Total counter for all free dispensed recipes

Paid

Cups

Total counter for all paid dispensed recipes

Jug

Cups

Total counter for all dispensed jugs

Rinse counter

Mixer(s)

Number of mixer rinses

Reset counter

Total rest of all counters

1.4 Quick recipe

Recipe name  1

Recipe name  10

Cup volume

50-250 ml

120ml

Use this for setting the volume and strength of cof-
fee, milk, sugar and cocoa easily per recipe (drink 
button).
Only the ingredients applicable to the recipe are 
shown.

Ingredient 1

-20 / +20%

0%

Ingredient 2

-20 / +20%

0%

Ingredient 3

-20 / +20%

0%

Ingredient 4

-20 / +20%

0%

1.6 Software

Software version is readable here.

1.7 PIN-code

2-2-2-2-2

PIN code = press the number 2 key  ve times.

 

 

 

Escape 

(back without con rming any changes)

Previous 

(menu item / increase value)

Next 

(menu item / decrease value)

Enter 

(con rm menu choice)

Test 

(press for 1 sec.)

From Software V4.00 the menu items are bounded in a 
‘loop’

To leave the Operator menu; press the X-button ones.

To leave the Service menu; press the X-button twice. 
This means its not necessary anymore to press the 
menu button on the inside of the service key panel when 
leaving the menu.

When changes where made a long beep-signal follows 
to indicate that the settings are stored in the memory.

TEST

PIN: 2-2-2-2-2

X

X



Summary of Contents for OPTIVEND 2009

Page 1: ...NL GB D F Service boek Service book Servicehandbuch Manuel de service maintenance M o d e l 2 0 0 9...

Page 2: ...ater dispensing 48 1 4 Cold water dispensing optional 48 1 5 Ingredients and mixer system 48 1 6 Evaporation extractor system 49 1 7 Solid state relay SSR 49 1 8 Steam thermostat 49 2 MENU STRUCTURE 5...

Page 3: ...ve this document with the user after installation and to change the standard factory PIN code All sections and paragraphs are numbered The various gures referred to in the text can be found in the gur...

Page 4: ...l amount of rinsing water is released shortly after dispensing to rinse away any ingredient residue 1 4 Cold water dispensing optional OptiVend has a built in cold water option special base cabinet wi...

Page 5: ...ll automatically revert to standby mode Sat On 00 00 Off 00 00 Sun On 00 00 Off 00 00 1 3 Recipe counters Recipe 1 Recipe 10 Total Off 00 00 Total counter for recipe 1 free paid jugs Free Cups Number...

Page 6: ...bination with a hot cold water recipe button Drip time 0 10 sec 2 sec The length of time that the product continues to run from the brewer or mixer After this time has elapsed a new drink selection ca...

Page 7: ...V HS DUO Hysteresis 2 10 C 2 C Temperature drop after which boiler must reheat Output block 70 80 C 78 C Boiler temperature disables dispens ing Display Out of order boiler heating Output release 70 8...

Page 8: ...s menu item to the operator menu I 0 Quick recipe Yes no Yes Add Quick recipe menu item to the operator menu Drip tray sign 1 Yes no Yes Turns off drip tray sensor software Demo modus 3 Yes no No This...

Page 9: ...the new model settings will be activated When you con rm this setting all loaded factory settings and changed programmed values will be lost After loading defaults the PIN code reverts to 2 2 2 2 2 a...

Page 10: ...remove the quick recipe from the operator menu if desired Go to 2 4 Settings 2 4 9 I 0 Quick recipe via the service menu and change Yes into No 3 2 Model code system The OptiVend models have the foll...

Page 11: ...e Sugar Espresso Sugar Soup Soup Soup only if the necessary ingredient s are available in the canisters Tea Tea Tea Table 5 OptiVend 1 TS TL OptiVend 2 TS OptiVend 3 TS Hot Cold OptiVend 4 TS Hot Cold...

Page 12: ...sters 1 Coffee Coffee Coffee Coffee Coffee 2 Topping Chocolate 3 Coffee Coffee Coffee Topping Topping 4 Topping Chocolate Sugar Sugar Button 3 1 3 1 3 4 1 2 1 3 4 1 3 4 Standard recipes 1 Coffee Black...

Page 13: ...1 1 OptiVend Choco Unit 1 DV 1 Mixer 1 1 DV 4 Hot water OptiVend 1 Unit 1 DV 1 Mixer 1 DV 4 Hot water 1 2 OptiVend 2 DV 2 Mixer 2 DV 4 Hot water 3 Unit 1 Unit 2 OptiVend 1 TS 1 TL DV 1 DV 2 Mixer 1 M...

Page 14: ...allation set a parameter for the device to be serviced See Service Menu item 2 8 Descale lter Use the table below to set the correct service parameter Service parameter reached The dispensed drinks ar...

Page 15: ...e Table 8 WARNING Do not leave the device during maintenance work When descaling always follow the instructions for the descaler used It is advisable to wear safety goggles and protective gloves when...

Page 16: ...clean water Repeat instruction 10 one more time to rinse the reservoir completely free of acid 13 Turn on the device again the reservoir will re ll with clean water Allow the water reservoir to heat u...

Page 17: ...INGREDIENT MOTORS MIXERS 4 3 FAN INLET OUTPUTS G13 MDB RS232 COMMUNICATION POWER SUPPLY MICROCONTROLLER J15 J6 J2 USB J4 2 1 TEMP1 2 1 4 3 24V DC KEY DISPLAY INPUTS J12 J7 J16 J1 F1 BATT F6 3AT 1 2 3...

Page 18: ...Take care to rotate in the right direction Shared 24 DC red wire on red spot on Mixer and Ingredients Motor 15 16 Mixer 2 Violet 13 14 Mixer 3 11 12 Ingredient Motor 1 Brown 9 10 Ingredient Motor 2 G...

Page 19: ...f order Boiler heating The boiler temperature is temporarily too low because too much water has been used Once the temperature is restored the message automatically disappears and the drink selection...

Page 20: ...unication be tween machine and MDB payment system Check the connection between the machine and MDB payment system Out of order E18 mixer FET error Mixer motor output remains active Mixer motor output...

Page 21: ...epting Euros and Tokens Carry out section 8 1 3 and 8 1 4 beforehand Open the service menu Set a price using menu 2 2 Button settings Button 1 12 Price e g 0 50 The recipe buttons are activated after...

Page 22: ...coin changer suitable for euros 0 05 2 00 Other currencies are available on request The coin changer has 6 coin tubes 0 05 2x 0 10 0 20 0 50 1 00 1 Return button 2 Coin insert 3 Lock 4 Change 8 2 1 T...

Page 23: ...eadof ce Dr A F Philipsweg 47 P O Box 71 9400 AB Assen The Netherlands Tel no 31 0 592 376376 Fax no 31 0 592 341751 E mail info animo nl Internet http www animo eu Rev 7 4 06 2011 Art nr 09897 M o d...