ComBi-Line
7.
FLOW HEATER SYSTEM
When a flow heater [1] is switched on, the water is heated until it has reached the boiling point (100
°C). The hot water automatically goes up into the swivel arm and makes way for fresh cold water from
the cold water reservoir, which is connected to the inlet. The continuous flow water heater is activated.
No temperature regulation is necessary. The water from the boiled water output (top) [1.1] is always at
the boiling point.
Major components
Art. no.
Technical data
Material
1. Flow heater CB5
03221
3x230 V / 400 V - 3 kW
st.st.
Flow heater CB10
03222
3x230 V / 400 V - 6 kW
st.st.
Flow heater CB20
03223
3x230 V / 400 V - 9 kW
st.st.
1.1 Boiled water output (top)
st.st.
1.2 Bulb pocket
st.st.
1.3 Cold water inlet (bottom)
st.st.
1.4 Heating elements
st.st.
2. Boil-dry protection with reset
03089
3x16 A / 90° -7K
2.1 Temperature bulb
st.st.
2.2 Electrical cut off
3. Power relays (3x)
1004596 1x25 A - 250 Vac / 24 Vdc
1.3
1
2.1
90°C
1.4
1.2
2.2
1.1
2
1.4
L1
L 2
L 3
N
3