- 19 -
3378750_ut_GB
ENGLISH
GB
TABLE OF ALARM INDICATIONS
If the problem or fault noticed is not amongst those
listed in the table, consult the “Key to Alarms” table
provided below.
The information provided below s intended to identify
the alarm signals which appear on the display
(11)
.
Important
Press button (14) to reset the alarm and the
cooking cycle restarts automatically; if this is not
the case, press the start key (2).
REAL
INJ
2
11
14
FAULT
TROUBLESHOOTING
The appliance has been tested before being put into service.
The information provided below is intended to assist in the identifi cation and correction of any
anomalies and malfunctions which might occur during use.
The user can solve some of these problems himself, but for others specifi c technical knowledge
or skill is required, and so they must only be carried out by qualifi ed staff with recognised
experience acquired in the specifi c sector of operation.
Important
For all requirements contact the agents or the headquarters of Angelo Po which can be
found in the contacts section of the website http://www.angelopo.com.
Fault
Cause
Remedy
The appliance does not
switch on
Fuse “blown”
Replace the fuse (see “installation
manual”).
Safety or protection device (safety
thermostat or overload cutout)
tripped.
Press device reset button.
Electronic circuit board damaged
Contact the after-sales service.
Smell of gas
Gas leaks in supply system
Check the tightness of the system
Cooking cycle does not start
or stops suddenly
Control board electronic circuit
board damaged
Contact the after-sales service
Alarm triggered
Consult the “Key to Alarms” table
The burner does not light or
goes out suddenly
Gas valve faulty
Replace gas valve
Air intake in base obstructed
Clean the air intake
Burner does not light or goes
out suddenly with “E12”
alarm signalled
Ignition plug wires disconnected
or damaged
Reconnect or replace the wires
Ignition plugs dirty or damaged
Clean or replace the plugs
Ignition monitoring device faulty
Replace the device