![Angelo Po BC101LU Use And Installation Manual Download Page 23](http://html.mh-extra.com/html/angelo-po/bc101lu/bc101lu_use-and-installation-manual_2943524023.webp)
23
3283430_GB
PROGRAM I.F.R.
The IFR is an innovative patented system of positive quick cooling which allows the
cycle optimized for each type of foodstuffs
by preventing superficial freezing
.
Temperatures are detected by a three-sensor multipoint needle probe. The position
inside the foodstuff is determined univocally by a reference disk located along the needle.
(ref. par. “
Core
probe
”
).
1.
Select the desired cycle by rotating the
knob
SOFT 0°F
HARD 0°F
MENU
INFINITY
SOFT +37°F
HARD +37°F
IFR
2.
Press the knob to activate the selected
cycle
During the cycle it is possible:
- select SET to change the fan speed
- to stop the cycle by selecting STOP
Note: the modified value will only be saved for the
cycle in progress
SOFT 0°F
HARD 0°F
MENU
INFINITY
SOFT +37°F
HARD +37°F
IFR
- -
IFR
100%
+80°F
+75°F
SET
STOP
3.
Cycle ended, automatic conservation
phase
During conservation it is possible:
- to view and modify the default parameters by
selecting SET (see page 41)
- to activate a manual defrost by selecting
- to stop the cycle by selecting STOP
Note: the modified parameters will be saved
only for the cycle in progress.
If not required, manual defrosting is not
performed
- -
END CYCLE
CONSERVE
100%
+80°F
+75°F
SET
STOP
Summary of Contents for BC101LU