GPC-14/18
PASTA COOKER
CLEANING & MAINTENANCE
DAILY CLEANING
1.
Follow shutdown procedure and allow hot water to cool.
2.
Disconnect the power supply.
3.
Open the front door and thread the drain valve extension into the drain valve.
4.
Slowly open drain valve and drain water.
CAUTION: HOT WATER!
5.
Wipe out and rinse tank.
6.
Close drain valve and remove extension.
7.
Refill tank with clean water.
8.
Follow the lighting procedure.
NOTE:
The cooker automatically shuts off the burners when you open the door so that they cannot fire.
After draining or maintenance, close the door and reset the unit by turning the power switch off and then on.
MONTHLY MAINTENANCE
1.
Each month, before operation, check the exhaust flue to ensure that it is clear of debris and obstructions allowing exhaust gases to flow freely
toward the ventilation hood area. DO NOT allow the flue area to become excessively dirty.
2.
Observe the condition of the ventilation hood. If it shows evidence of a great deal of greasy residue, remove (clean) the residue to allow free
flow of ventilation air.
3.
Check the burner tube baffles (located inside the burner tube on 18”/20” tube fired models) to ensure that they are not deteriorated beyond
their useful life. If baffles need to be replaced, contact the factory, a factory representative or a local service company for replacement.
SERVICE INSTRUCTIONS
DO NOT OPERATE UNIT IN THE EVENT OF A POWER FAILURE.
1.
Follow the shut-down procedure in the event of a prolonged power failure.
2.
Disconnect the power supply before service or maintenance.
3.
When supplied with casters, a restraining device should be in place. If disconnection of the restraint is required, reconnect the restraint after
the appliance has been returned to its originally installed position.
4.
To avoid splashing of hot liquid, before removing the unit from its originally installed location:
a.
shut down the unit in accordance with the shutdown procedure
b.
close all valves
c.
allow to cool
d.
drain the liquid
e.
disconnect the restraining device
5.
Contact the factory, a factory representative, or local service company to perform maintenance or repairs.
DANGER!
Avoid moving the unit while it contains hot liquid. Drain the liquid before cleaning or servicing.
WARNING!
Wait until the tank has cooled before performing step 5 to avoid injury from burns.
Summary of Contents for PASTA PRO GPC-14
Page 8: ......