PROBLEM 

 

Water is cold 
(Burners not firing) 

 
 
 
 
 
 
 
 

Thermostat 25º F or more below the knob 
set point. 

 
 
 
 
 
 

Pilot will not remain lit. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Burner flames too large. 

CAUSE 

 

No gas supply 

Inadequate gas supply 

 
 

No Pilot 

 

Safety valve knob is in the “Pilot” position 

 
 

Thermostat is set too low. 

Low supply gas pressure. 

Defective thermostat 

 
 
 

Loose wiring 

 

Pilot flame is too small and will not heat the 
thermopile. 

 
 
 

Dirty pilot burner 

High-limit safety activated 

 

High-limit safety defective 

 

WA

DO NOT return the fryer to operati 

 

Thermopile is defective. 
(Thermopile should generate at least 
250mV) 

 

Gas safety valve is defective. 

 

Main gas valve pressure regulator set too 
high. 

SOLUTION 

 

Open all gas cocks supplying the unit. 

Adjust the pressure regulator for 3.5 inches W.C. 
manifold pressure for Natural Gas and 10 inches 
W.C. for L.P. gas, with the burners firing. 

Follow lighting instructions under LIGHTING 
AND SHUT DOWN section. 

If the pilot is burning turn the knob to the “ON” 
position. 

 

Turn the thermostat knob to a higher set-point. 

Check incoming gas pressure. 

If the pilot is burning, the safety valve knob is 
“ON”, and the thermostat knob is at the highest 
set-point, the burners should be firing.  If not, 
replace the thermostat. 

 

Check wires to make sure they are intact, and 
tighten all connections 

Adjust the pilot needle valve on the gas safety 
valve to the full open position (it is located under 
the slotted screw).  To adjust, remove the slotted 
screw turn the inside needle valve open 
(counter-clockwise) two turns.  Replace the outer 
screw. 

Remove pilot burner and clean. 

Allow water to cool for 15 minutes, then follow 
lighting instructions 

Jump out high limit.  If pilot then lights, replace 
high limit. 

 

RNING! 

on with its high limit thermostat bypassed! 

 

Replace the thermopile. 

 
 
 

Replace the gas safety valve 

 

Reduce the pressure by adjusting the pressure 
regulator.  To reduce the pressure, turn the 
adjusting slot counter-clockwise.  The adjusting 
slot is located under the regulator slotted cap. 

Summary of Contents for PASTA PRO GPC-14

Page 1: ...nformation must be posted in a prominent location WARNING Improper installation adjustment alteration service or maintenance can cause property damage injury or death Read the installation operating a...

Page 2: ...the unit for the appliance wiring diagram LEG CASTER INSTALLATION 1 Carefully lay cooker on its back and install legs or casters as shown in diagram A below 2 After placing unit in installation area a...

Page 3: ...t be obstructed The bottom and back of the unit must be kept open so that the burners will be able to draw enough air for proper operation The area directly in front of the unit must be kept open so t...

Page 4: ...Pilot must be turned off if cook tank is empty POWER BURST 18 and 20 Pasta Cookers are equipped with the Power Burst System The Power Burst toggle switch is located on the front of the unit Hard Boil...

Page 5: ...eck the burner tube baffles located inside the burner tube on 18 20 tube fired models to ensure that they are not deteriorated beyond their useful life If baffles need to be replaced contact the facto...

Page 6: ...under LIGHTING AND SHUT DOWN section If the pilot is burning turn the knob to the ON position Turn the thermostat knob to a higher set point Check incoming gas pressure If the pilot is burning the sa...

Page 7: ...wire and NO right motor blue left motor brown If the motor operates the timer has failed and must be replaced If the motor does not operate the microswitch or motor may have failed Set a time value us...

Page 8: ......

Page 9: ...NOTES...

Page 10: ...please contact the Anets your equipment please contact the Anets factory at Authorized Service and Parts representative 603 225 6684 World Wide ASAP covering your area or contact Anets Website Address...

Reviews: