background image

4 L20-386 

R2 

 

FILTER MATE TANK 

Filter envelope clip 

 

Lift out handle 

 

Quick connect coupling 

Knurled retaining nut 

 
 
 
Pump quick-connect coupling 

Filter envelope 

 
 
 
 
 

Return line and optional hose 

connection 

 
 
 
 
 

FILTRONIC II TANK 

 
 
 
 
 
 

Pump quick-connect coupling 

 

Filter envelope 

 

Filter envelope clip 
 

 

 

 

Lift out handle 

 
 

Quick connect coupling 

Knurled retaining nut 

 
 
 
 

Summary of Contents for GoldenFRY Filt II-14

Page 1: ...talling or servicing this equipment WARNING After installation of this equipment immediately contact your local gas supplier to obtain information about what action to take whenever any person smells...

Page 2: ...Filt II 14 14 Filtronic Filter System in Cabinet Filt II 14W 14 Filtronic Filter System with Heat Lamp Filt II 18 18 Filtronic Filter System in Cabinet Filt II 18W 18 Filtronic Filter System with Heat...

Page 3: ...into a properly grounded three prong receptacle DO NOT cut or remove the grounding prong from this plug FILTER UNIT PREPARATION Refer to Photos On Page 4 1 Assemble filterenvelopetofilterscreenbyslid...

Page 4: ...ndle Quickconnectcoupling Knurledretainingnut Pumpquick connectcoupling Filter envelope Returnlineandoptionalhose connection FILTRONIC II TANK Pumpquick connectcoupling Filter envelope Filterenvelopec...

Page 5: ...g handledcleaningbrushtowipethebottom ofthefryerandpushexcesscrumbsthroughthedrainandintothefiltermachine 4 Whentheshorteningreturningintothefryerisclear closethedrainvalve blackhandle andallowthe fry...

Page 6: ...ntrol panel must be reset for the fryer to operate again 8 The other fryers in the bank can be filtered using the same procedure IMPORTANT NOTE Thepumponthisfilterunitisequippedwithasafetythatwillturn...

Page 7: ...ectcouplingondraintubefromknurledretainingnut 8 Detachknurledretainingnutfromfittinginscreen 9 Remove filter envelope clipfrom end of filterscreen and folded back endof envelope 10 Removefilterenvelop...

Page 8: ...move the motor from the filter and bench test by connecting a 120V line to the motor leads If it runs the problem is with the wiring between the motor and the power supply If it does not run the motor...

Page 9: ...electrical connections normally associated with initial installation These procedures are outlined in the manual and are NOT covered by warranty If it is damaged due to flood fire or other acts of God...

Page 10: ...e Website Address www anets com MAILING ADDRESS P O BOX 501 CONCORD NH 03302 0501 SHIPPING ADDRESS 10 FERRY ST CONCORD NH 03301 In the event of problems with or questions about your equipment please c...