18
D -
WALL MOUNTING TYPE
1. Remove the dust proof caps (B,E,F,H,I on page 21)
2. Detach the pump assembly from bracket by removing Hex. Bolts (M6).
3. Flip the bracket and assemble the pump to the right position on bracket by using Hex. Bolts (M6).
4. Connect the drain hose to the two-way valve for paint recirculation. (as COMMON 1)
5. Connect the suction hose to the paint inlet joint.
Hex. Bolt (M6)
Bracket
Drain hose
Suction
hose
E -
GRAVITY HOPPER TYPE (6 LT.)
1. Assemble the hopper set by means the “U” suction tube, to the paint inlet joint of the pump mounted on cart.
2. Connect the drain hose from two-way valve for paint recirculation to hopper lid set directly.
2