Anest Iwata AP-96-05 Instruction Manual Download Page 9

- 9 - 

 

 

WARNING

 

 

 

Other precautions 

 

1

Never alter this airless pole gun. 

If done, it can cause insufficient performance and failure. 

2

Enter working areas of other equipment (robots, reciprocators, etc.) after machines are turned off. 

If not, contact with them can cause injury. 

3

Never spray foods or chemicals through this gun. 

If done, it can cause accident by corrosion of fluid passages or adversely affect health by mixed foreign matter. 

4.

 

Securely connect fluid hose. 

       

If hose is disconnected during operation, hazardous hose movement and paint ejection will cause severe bodily injury. 

5

If something goes wrong, immediately stop operation and find the cause.    Do not use again until you have solved the 

problem. 

 

 

 

 

2. Name of components and checking the product 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

W hen you open the package, be sure to check that all goods are included and are in good 

condition. 

If  there  is  any  damage  or  missing  components,  do  not  use  the  product  to  avoid  danger 

and immediately contact the distributor who sold it to you. 

Always keep caution plates (warning display) in good condition and clean. 

If they are damaged or missing, replace with new ones. 

S e c u r e l y   c o n nect
  fluid  hos e.      

Summary of Contents for AP-96-05

Page 1: ...120...

Page 2: ......

Page 3: ......

Page 4: ...cm cm MPa cm ml sec cm...

Page 5: ...3 4 1 3 5 1 3 6 1 3 7 1 3 8 1 4 1 1 4 2 1 4 3 1 4 4 1 5 1 6 1 1 6 2 1 6 3 1 6 4 1 7 1 8 1 9 1 10 1 11 2 12 1 12 1 1 12 2 1 12 3 8 12 4 1 12 5 1 12 6 1 12 7 1 12 8 1 12 9 1 13 1 14 1 15 1 16 1 17 1 18...

Page 6: ...rranty is valid only in Japan 14 11 18 3 4 16 16 12 6 11 5 3 3 12 7 12 6 18 12 1 3 4 kgf cm2 12 8 0800 100 1926 0120 917 144 9 00 12 00 13 00 17 00 http www anest iwata co jp No 1076 08 No 03296224 22...

Page 7: ...40PSI Tested with water Air Fluid Measuring point 1m backwards from gun m height Main specifications Model Max operating pressure MPa bar PSI Pole length m Use Fluid output ml min Fluid hose connectio...

Page 8: ...per operation or scattering cleaning liquid In order to release pressure first stop supply of fluid and thinner to airless pole gun Protection of human body 1 Use in a well ventilated site by using sp...

Page 9: ...isconnected during operation hazardous hose movement and paint ejection will cause severe bodily injury 5 If something goes wrong immediately stop operation and find the cause Do not use again until y...

Page 10: ...free pattern tip each tip optional Refer to 4 and prepare nozzle tip separately Be sure to stop pump reduce fluid pressure down to 0 pressure and securely apply safety lock of airless pole gun before...

Page 11: ...t except ALG 73 Remove No 12 handle from gun body Remove and clean No 11 filter set 4 Selection of nozzle tip according to kind of paint H I N T Numbering system Pattern width 25 cm at 30cm spray dist...

Page 12: ...g used Replace with new tip or proper sized tip Paint does not stop smoothly Pump pressure is too high Reduce paint pressure down to 25 MPa 250bar 3 626PSI Paint leaks from the gun tip Paint sticks to...

Page 13: ...3 6 nozzle seat spring 1 12 6 needle packing 2 3 7 O ring 1 12 7 needle packing seat 1 3 8 spring seat 1 12 8 needle packing holder 1 4 1 fluid pipe set 1 for 05 12 9 screw 1 4 2 fluid pipe set 1 for...

Page 14: ...14 Manual No 1076 08 Code No 03296224 3176 Shinyoshida cho Kohoku Ku Yokohama 223 8501 Japan...