6. Parts list 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

  marked parts are consumable parts. 

 

No.  Part name 

Q’ty  Remarks   

No.  Part name 

Q’ty  Remarks 

 1 

hand guard 

1   

 10 

gun body 

1   

 2 

nozzle holder 

1   

 11 

needle seat 

2   

 3 

swivel head 

1   

 12 

fluid needle set 

1   

 3-1  nozzle gland   

1   

 12-1  needle stem 

1   

 3-2  nozzle gland holder 

1   

 12-2  conical spring holder 

1   

 3-3  fluid needle set 

1   

 12-3  conical spring washer 

1   

 3-4  L packing 

1   

 12-4  packing holder 

1   

 3-5  packing seat 

1   

 12-5  sub packing 

1   

 3-6  nozzle seat spring 

1   

 12-6  needle packing 

2   

 3-7  O ring 

1   

 12-7  needle packing seat 

1   

 3-8  spring seat 

1   

 12-8  needle packing holder 

1   

 4-1  fluid pipe set 

1  for 05 

 12-9  screw 

1   

 4-2  fluid pipe set 

1  for 10 

 13 

needle spring   

1   

 4-3  fluid pipe set 

1  for 15 

 14 

needle spring seat 

1   

 4-4  fluid pipe set 

1  for 20 

 15 

packing 

1   

 5 

needle tip seat 

1   

 16 

filter set 

1   

 6-1  needle bar 

1  for 05 

 17 

handle (grooved,black) 

1   

 6-2  needle bar 

1  for 10 

 18 

universal joint (G1/4) 

1   

 6-3  needle bar 

1  for 15 

 19 

trigger stud 

1   

 6-4  needle bar 

1  for 20 

 20 

hex.cap nut 

2   

 7 

hex.nut 

1   

 21 

trigger set 

1   

 8 

joint 

1   

 22 

caution plate 

1   

 9 

safety guard 

1   

 23 

Nameplate 

1   

Summary of Contents for AP-96-05

Page 1: ...120...

Page 2: ......

Page 3: ......

Page 4: ...cm cm MPa cm ml sec cm...

Page 5: ...3 4 1 3 5 1 3 6 1 3 7 1 3 8 1 4 1 1 4 2 1 4 3 1 4 4 1 5 1 6 1 1 6 2 1 6 3 1 6 4 1 7 1 8 1 9 1 10 1 11 2 12 1 12 1 1 12 2 1 12 3 8 12 4 1 12 5 1 12 6 1 12 7 1 12 8 1 12 9 1 13 1 14 1 15 1 16 1 17 1 18...

Page 6: ...rranty is valid only in Japan 14 11 18 3 4 16 16 12 6 11 5 3 3 12 7 12 6 18 12 1 3 4 kgf cm2 12 8 0800 100 1926 0120 917 144 9 00 12 00 13 00 17 00 http www anest iwata co jp No 1076 08 No 03296224 22...

Page 7: ...40PSI Tested with water Air Fluid Measuring point 1m backwards from gun m height Main specifications Model Max operating pressure MPa bar PSI Pole length m Use Fluid output ml min Fluid hose connectio...

Page 8: ...per operation or scattering cleaning liquid In order to release pressure first stop supply of fluid and thinner to airless pole gun Protection of human body 1 Use in a well ventilated site by using sp...

Page 9: ...isconnected during operation hazardous hose movement and paint ejection will cause severe bodily injury 5 If something goes wrong immediately stop operation and find the cause Do not use again until y...

Page 10: ...free pattern tip each tip optional Refer to 4 and prepare nozzle tip separately Be sure to stop pump reduce fluid pressure down to 0 pressure and securely apply safety lock of airless pole gun before...

Page 11: ...t except ALG 73 Remove No 12 handle from gun body Remove and clean No 11 filter set 4 Selection of nozzle tip according to kind of paint H I N T Numbering system Pattern width 25 cm at 30cm spray dist...

Page 12: ...g used Replace with new tip or proper sized tip Paint does not stop smoothly Pump pressure is too high Reduce paint pressure down to 25 MPa 250bar 3 626PSI Paint leaks from the gun tip Paint sticks to...

Page 13: ...3 6 nozzle seat spring 1 12 6 needle packing 2 3 7 O ring 1 12 7 needle packing seat 1 3 8 spring seat 1 12 8 needle packing holder 1 4 1 fluid pipe set 1 for 05 12 9 screw 1 4 2 fluid pipe set 1 for...

Page 14: ...14 Manual No 1076 08 Code No 03296224 3176 Shinyoshida cho Kohoku Ku Yokohama 223 8501 Japan...

Reviews: