3. Painting job
3-1 Connect fluid hose.
WARNING
Securely connect fluid hose. W hen paint leaks, never try to stop it by
hand / In that case, stop pump immediately and reduce paint pressure
down to 0 pressure .
Be sure to use air hose with built-in ground wire or fluid hose with built-in
ground wire or use grounded gun stay in order to connect ground.
CAUTION
Before using a new airless spray gun, clean inside of the new airless spray
gun. If not, rust preventive inside airless spray gun can cause painting
failure.
3-2
Fitting or removing nozzle tip or free pattern tip (each tip optional).
※
Refer to 4 and prepare nozzle tip separately.
Be sure to stop pump, reduce fluid pressure down to 0 pressure and
securely apply safety lock of airless pole gun before you fit or remove
nozzle tip.
※
Refer to instruction manual of free pattern tip.
3-3 Painting job
WARNING
During painting, be sure to wear protective cover such as glasses, mask or
gloves to avoid serious injury caused by paint or solvent which might enter
your eyes or you might inhale.
H I N T
!
As fluid pressure increases, paint mist becomes finer and finishing
becomes better. But on the other hand, high pressure can be dangerous
and precipitate corrosion of equipment and nozzle tip. Adjust pressure as
low as possible as far as finish is satisfactory.