3. Painting job 

 

 

3-1 Connect fluid hose. 
 

 

WARNING

 

Securely  connect  fluid  hose.    W hen  paint  leaks,  never  try  to  stop  it  by 
hand  /  In  that  case,  stop  pump  immediately  and  reduce  paint  pressure 
down to 0 pressure . 
Be  sure  to  use  air  hose  with  built-in  ground  wire  or  fluid  hose  with  built-in 
ground wire or use grounded gun stay in order to connect ground. 

 

CAUTION

 

Before using  a  new  airless spray gun,  clean  inside of  the new airless  spray 
gun.  If  not,  rust  preventive  inside  airless  spray  gun  can  cause  painting 
failure.

 

 
 
 

3-2

 

Fitting or removing nozzle tip or free pattern tip (each tip optional). 

  Refer to 4 and prepare nozzle tip separately. 

 

Be  sure  to  stop  pump,  reduce  fluid  pressure  down  to  0  pressure  and 
securely  apply  safety  lock  of  airless  pole  gun  before  you  fit  or  remove 
nozzle tip.

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

※  

Refer to instruction manual of free pattern tip. 

 

 

3-3 Painting job 

 

WARNING

 

During painting, be  sure to  wear  protective cover such  as glasses,  mask  or 
gloves  to  avoid  serious  injury  caused  by  paint  or  solvent  which  might  enter 
your eyes or you might inhale. 

H I N T 

!

 

As  fluid  pressure  increases,  paint  mist  becomes  finer  and  finishing 
becomes  better.  But  on  the  other  hand,  high  pressure  can  be  dangerous 
and  precipitate  corrosion  of  equipment  and  nozzle  tip.  Adjust  pressure  as 
low as possible as far as finish is satisfactory. 

 

Summary of Contents for AP-96-05

Page 1: ...120...

Page 2: ......

Page 3: ......

Page 4: ...cm cm MPa cm ml sec cm...

Page 5: ...3 4 1 3 5 1 3 6 1 3 7 1 3 8 1 4 1 1 4 2 1 4 3 1 4 4 1 5 1 6 1 1 6 2 1 6 3 1 6 4 1 7 1 8 1 9 1 10 1 11 2 12 1 12 1 1 12 2 1 12 3 8 12 4 1 12 5 1 12 6 1 12 7 1 12 8 1 12 9 1 13 1 14 1 15 1 16 1 17 1 18...

Page 6: ...rranty is valid only in Japan 14 11 18 3 4 16 16 12 6 11 5 3 3 12 7 12 6 18 12 1 3 4 kgf cm2 12 8 0800 100 1926 0120 917 144 9 00 12 00 13 00 17 00 http www anest iwata co jp No 1076 08 No 03296224 22...

Page 7: ...40PSI Tested with water Air Fluid Measuring point 1m backwards from gun m height Main specifications Model Max operating pressure MPa bar PSI Pole length m Use Fluid output ml min Fluid hose connectio...

Page 8: ...per operation or scattering cleaning liquid In order to release pressure first stop supply of fluid and thinner to airless pole gun Protection of human body 1 Use in a well ventilated site by using sp...

Page 9: ...isconnected during operation hazardous hose movement and paint ejection will cause severe bodily injury 5 If something goes wrong immediately stop operation and find the cause Do not use again until y...

Page 10: ...free pattern tip each tip optional Refer to 4 and prepare nozzle tip separately Be sure to stop pump reduce fluid pressure down to 0 pressure and securely apply safety lock of airless pole gun before...

Page 11: ...t except ALG 73 Remove No 12 handle from gun body Remove and clean No 11 filter set 4 Selection of nozzle tip according to kind of paint H I N T Numbering system Pattern width 25 cm at 30cm spray dist...

Page 12: ...g used Replace with new tip or proper sized tip Paint does not stop smoothly Pump pressure is too high Reduce paint pressure down to 25 MPa 250bar 3 626PSI Paint leaks from the gun tip Paint sticks to...

Page 13: ...3 6 nozzle seat spring 1 12 6 needle packing 2 3 7 O ring 1 12 7 needle packing seat 1 3 8 spring seat 1 12 8 needle packing holder 1 4 1 fluid pipe set 1 for 05 12 9 screw 1 4 2 fluid pipe set 1 for...

Page 14: ...14 Manual No 1076 08 Code No 03296224 3176 Shinyoshida cho Kohoku Ku Yokohama 223 8501 Japan...