Battery equalization voltage
3.2KVA default setting: 29.2V
5KVA default setting: 58.4V
Setting range is from 25.0V to 31.5V for 3.2KVA model and 48.0V
to 61.0V for 5KVA model. Increment of each click is 0.1V.
33
Battery equalized time
60min (default)
Setting range is from 5min to 900min.
Increment of each click is 5min.
34
Battery equalized timeout
120min (default)
Setting range is from 5min to 900 min.
Increment of each click is 5 min.
35
Equalization interval
30days (default)
Setting range is from 0 to 90 days.
Increment of each click is 1 day
36
Equalization activated
immediately
Enable
Disable (default)
If equalization function is enabled in program 30, this program can
be set up. If “Enable” is selected in this program, it’s to activate
battery equalization immediately and LCD main page will shows
“
”. If “Disable” is selected, it will cancel equalization function
until next activated equalization time arrives based on program 35
setting. At this time, “
” will not be shown in LCD main page.
50
AC charger ON timer
AC charger start from 00:00 to
23:00. (Default 00:00)
51
AC charger OFF timer
AC charger stops from 00:00 to
23:00. (Default 00:00)
52
AC output ON timer
AC output on from 00:00 to
23:00. (Default 00:00)
53
AC output OFF timer
AC output off from 00:00 to
23:00. (Default 00:00)
54
Real time setting---Minute
Default 00, range 00~59
55
Real time setting---Hour
Default 00, range 00~23
56
Real time setting---Date
Default 01, range 01~31
57
Real time setting---Month
Default 01, range 01~12
58
Real time setting---Year
Default 16, range 16~99