Function Buttons

Short press to switch among functions.
Long press to enter in V.F.C function.

Short press to change range.
Push for more than 2 seconds to enter the
relative mode. The product will store the present
reading as a reference for subsequent readings.
The display is zeroed, and the stored reading is
subtracted from all subsequent readings. Long-
push again to exit the relative mode.

Press this button to switch MAX/MIN test. Long 
press 2 second to quit MAX/MIN mode.

Push once to hold the current reading on the
display; push again to continue normal operation.
Long press beyond 2 seconds to turn on 
flashlight ; long press again to turn off flashlight.

Summary of Contents for SZ18

Page 1: ...All rights reserved Specifications are subject to change without notice User Manual...

Page 2: ...purchase This warranty does not cover fuses disposable batteries damage from misuse accident neglect alteration contamination or abnormal conditions of operation or handling including failures caused...

Page 3: ...Display 3 Function Buttons 5 Rotary Buttons 6 Input Terminals 8 Measurements Instruction 9 Measure AC DC Voltage 9 Measure AC DC Current 9 Measure Resistance 10 Test Diodes and Continuity 10 Measure C...

Page 4: ...test 14 Maintenance 15 Clean the Product 15 Replace the Batteries 15 Replace the Fuses 16 Specifications 17 General Specifications 17 Mechanical Specifications 17 Environmental Specifications 17 Elec...

Page 5: ...re you use the product Please use the product only as specified or the protection supplied by the product can be compromised Examine the case before you use the product Look for cracks or missing plas...

Page 6: ...changing the mode When the voltage to be measured exceeds 36V DC or 25V AC the operator shall be careful enough to avoid electric shock Misuse of mode or range can lead to hazards be cautious will be...

Page 7: ...s the range with the best resolution Manual range The user selects the range Capacitance test Farad Relative mode Diode test Continuity test Duty cycle test Secondary measurements display Alternating...

Page 8: ...rrent test Ampere Voltage test Volt Primary measurement display The product measures both sinusoidal and nonsinusoidal ac waveforms accurately Low battery Replace batteries Negative readings Display f...

Page 9: ...eference for subsequent readings The display is zeroed and the stored reading is subtracted from all subsequent readings Long push again to exit the relative mode Press this button to switch MAX MIN t...

Page 10: ...es 1 minute before auto power off To restart the product from auto power off press the SELECT button or turn the rotary switch back to the OFF position and then to a needed position To disable the Aut...

Page 11: ...20 1000 C 4 1832 Resistance 99 99M Continuity beeper will beep when resistance less than 50 Diode test Displays above 3V Capacitance 9 999mF NCV Square wave 50Hz 100Hz 200Hz 300Hz 400Hz 500Hz 600Hz 7...

Page 12: ...s to 9 999A A mA Input terminal for AC DC current measurements to 99 99mA COM Common return terminal for all measurements Input terminal for the measurements of 1 Diode 2 Continuity 3 Square wave 4 Te...

Page 13: ...cuit to measure the voltage 4 Read the measured voltage on the screen Measure AC DC Current 1 Connect the black test lead to the COM Terminal and the red lead to the A or A mA Terminal choose based on...

Page 14: ...he test lead to the Terminal 2 Turn the rotary to press SELECT to the Resistance Mode The screen will show 3 Touch the probes to the desired test points of the circuit to measure the resistance 4 Read...

Page 15: ...Connect the black test lead to the COM Terminal and the red lead to the Terminal 2 Turn the rotary to press SELECT to the capacitance Mode 3 Connect the red probe to the anode side and the black probe...

Page 16: ...function 10V 1 100KHz or turn the rotary switch to press SELECT to frequency test function 10V 1 5MHz 3 If the frequency between 100kHz and 5MHz press SELECT to enter AC mV position Touch the probes...

Page 17: ...isplay will show Fahrenheit 3 Touch the probes to the desired test points 4 Read the measured temperature on the display 13 Do not input voltage at this setting Test NCV 1 Turn the rotary to NCV posit...

Page 18: ...show voltage when put the test leads at the correct circuit Measure square wave 1 Connect the black test lead to the COM Terminal and the red lead to the Terminal 2 Turn the rotary switch to and the...

Page 19: ...nstructions Clean the Product Wipe the product with a damp cloth and mild detergent Do not use abrasives or solvents Dirt or moisture in the terminals can affect readings Remove the input signals befo...

Page 20: ...When a fuse is blown or do not work properly it shall be replaced as below 1 Remove the test leads and turn off the product before replacing the fuse 2 Loosen the four screws on the back cover and the...

Page 21: ...Times Second Ture RMS Data Hold Backlight Low Battery Indication Auto Power Off Mechanical Specifications Dimension 147 76 37mm Weight 191g without batteries Battery Type 1 5V AAA Battery 3 Warranty...

Page 22: ...Voltage V 999 9mV 0 1mV 0 5 3 9 999V 0 001V 99 99V 0 01V 999 9V 0 1V DC Voltage mV 9 999mV 0 001mV 99 99mV 0 01mV AC Voltage V 999 9mV 0 1mV 1 0 3 9 999V 0 001V 99 99V 0 01V 750 0V 0 1V AC Voltage mV...

Page 23: ...A 1 0 3 999 9mA 0 1mA DC Current A mA 99 99mA 0 01mA 9 999mA 0 001mA 99 99 A 0 01 A 999 9 A 0 1 A AC Current A mA 9 999A 0 001A 1 2 3 999 9mA 0 1mA AC Current A mA 99 99mA 0 01mA 9 999mA 0 001mA 99 99...

Page 24: ...99 99 0 01 1 0 3 999 9 0 1 0 5 3 9 999k 0 001k 99 99k 0 01k 999 9k 0 1k 9 999M 0 001M 1 5 3 99 99M 0 01M 3 0 5 Capacitance 9 999nF 0 001nF 5 0 20 99 99nF 0 01nF 2 0 5 999 9nF 0 1nF 9 999 F 0 001 F 99...

Page 25: ...nly to 100kHz under the ACV setting 9 999Hz 0 001Hz 0 1 2 99 99Hz 0 01Hz 999 9Hz 0 1Hz 9 999kHz 0 001kHz 99 99kHz 0 01kHz 999 9kHz 0 1kHz 5 000MHz 0 001MHz Duty Cycle 1 99 0 1 0 1 2 Temperature 20 100...

Page 26: ......

Reviews: