6. Maintenance

 

Page 42 

 

Manual

 MF0145AXA.doc

         Manual for ION-M17P/19P Advanced 

 

6.2.  Replacing the Fan Unit 

 
Replacement of the fan unit is not required as a preventative measure. Only if an 
alarm indicates a malfunctioning of a fan must the unit be exchanged. 

 

Note: 

Please observe that the fan unit can only be replaced as a whole. Do 
not remove the fans separately.

 

Read and observe chapter

 1.2 Health and Safety 

as well as the instructions in 

section 

6.1 General 

before starting with the replacement.  

 

1. 

Switch off the Remote Unit. Make sure mains is disconnected for the 
following replacement procedure.

 Then, proceed as follows: 

2. Loosen the four tallow-drop screws 

M4x8 by which the fan plate is 
screwed to the cabinet. Remove the 
four screws and the corresponding 
washers. 

 

 

 

3.  Remove the fan unit – by putting slight 

pressure on the fan plate cover – to a 
position that allows access to the fan 
connector and the earth-bonding 
cable.  

 
4.  Unscrew the fan connector and then 

disconnect the earth-bonding cable. 

 

 

 

 
 

Fan-unit connector 

Earth-bonding cable 

Summary of Contents for CommScope ION-M17P Advanced

Page 1: ...ION M17P 19P Advanced Optical Remote Unit M Cabinet Manual MF0145AXA...

Page 2: ...not cover the performance under adverse or disturbed conditions Should further information be desired or should particular problems arise which are not covered sufficiently for the purchaser s purpose...

Page 3: ...cal Installation 15 4 1 2 Property Damage Warnings for Mechanical Installation 15 4 1 3 Wall Mounting Procedure 17 4 1 4 Pole Mounting 18 4 1 5 Mounting of Fan Protection 20 4 2 ELECTRICAL INSTALLATIO...

Page 4: ...e 4 3 Pole mounting metric dimensions 19 figure 4 4 Mounting procedure for fan protection metric dimensions 20 figure 4 5 Connector flange of ION M17P 19P Advanced 22 figure 4 6 Grounding bolt left an...

Page 5: ...for Mobile Communication GND Ground GUI Graphical User Interface ICP3 Intercept Point 3rd order ID No Identification Number ION Intelligent Optical Network IP Ingress Protection ISO International Orga...

Page 6: ...avoid the possibility of close proximity to the antenna s while in operation 1 3 Property Damage Warnings 1 Attention Due to power dissipation the remote unit may reach a very high temperature Do not...

Page 7: ...in minus the loss between the repeater and the antenna PD mW cm is the allowed Power Density limit acc to 47 CFR 1 1310 B for general population uncontrolled exposures which is o F MHz 1500 for freque...

Page 8: ...itif Cet appareil est conforme avec Sant Canada Code de s curit 6 Le programme d installation de cet appareil doit s assurer que les rayonnements RF n est pas mis au del de I exigence de Sant Canada L...

Page 9: ...correct the interference at his own expense 8 Note This unit complies with European standard EN60950 Equipment Symbols Used Compliance Please observe the meanings of the following symbols used in our...

Page 10: ...hensive quality monitoring is conducted at all fabrication stages Finished products leave the factory only after a thorough final acceptance test accompanied by a test certificate guaranteeing optimal...

Page 11: ...o City Mexico Phone 1 815 546 7154 Cell 55 15 9104 7722 Office Phone 52 55 1346 1900 Office Fax 55 15 2102 4001 Fax 52 55 1346 1901 E mail wisupport commscope com E mail wisupport commscope com China...

Page 12: ...zerland Andrew Wireless Systems Austria GmbH CommScope Wireless Systems AG Mail Weglgasse 10 2320 Wien Schwechat Austria Mail Tiergartenweg 1 CH 4710 Balsthal Switzerland Phone 43 1706 39 99 10 Phone...

Page 13: ...aster Unit depends on the number of the Remote Units and the frequency range WDM Wave Division Multiplex filters are integrated in the optical modules For the UL a wavelength within 1546 nm 1550 nm is...

Page 14: ...rotective cover to be mounted over the air inlet is delivered with the unit For more details see section 4 1 5 Mounting of Fan Protection Mounting of the fan protection kit is only mandatory for outdo...

Page 15: ...falling due to improper installation The installer must verify that the supporting surface will safely support the combined load of the electronic equipment and all attached hardware and components T...

Page 16: ...er The specifications for stationary use of the Remote Unit must not be exceeded Ensure that the static and dynamic strengths are adequate for the environmental conditions of the site The mounting its...

Page 17: ...ver the screws Hang the mounting brackets of the Remote Unit into the screws and fasten them immediately using the washers and nuts Ensure that there is free access to the electrical connections as we...

Page 18: ...e the screw bands to fasten the two U beams to the pole as illustrated in figure 4 3 Pole mounting Note When fastening the U beams make sure that they are installed congruently and not at an angle to...

Page 19: ...ge 19 G0764M6 Lock for folding screw band ES 119 TESPA screw band stainless 11 mm Optical Remote Unit Washer DIN 125 Form B 8 0 Lock washer for M8 0 DIN 127 A2 Form B Hexagon nut M8 DIN 934 Pole Pole...

Page 20: ...ctive cover into the right position by fitting its four bore holes over the spacing bolts and fasten it using the original lock washers and screws of the Remote Unit These lock washers and screws are...

Page 21: ...disconnecting the mains connector at the Remote Unit ensure that mains power supply is disconnected 5 Attention Make sure that an appropriate circuit breaker acting as a disconnect device as required...

Page 22: ...front panels before connecting or disconnecting any cables 12 Notice Unused connectors must be closed with their protective covers to ensure watertightness 4 2 3 Connections figure 4 5 Connector flan...

Page 23: ...o connect external devices figure 4 6 Grounding bolt left and schematic view right After loosening the hex nut connect the earth bonding cable between the two washers as illustrated in the above Then...

Page 24: ...other tool e g a pair of pliers This might cause damage to the connector and lead to a malfunction of the RU Attention To minimize passive inter modulation PIM distortion attention has to be paid to...

Page 25: ...ocedure and do not show the actual RU 1 What is needed for the cleaning a Isopropyl alcohol b Compressed air c Lint free wipe d Cotton buds 2 Remove protective cap from the RF connector 3 Remove metal...

Page 26: ...ith isopropyl alcohol 6 Clean the inside surface of the inner ring with lint free wipe drenched with isopropyl alcohol 7 Clean the inside of the center conductor spring tines with a cotton bud drenche...

Page 27: ...chips and small particles from the mating and inner surfaces of the connector using compressed air 10 Continue with the winding area using lint free wipe drenched with isopropyl alcohol 11 Continue wi...

Page 28: ...strate the connection procedure and do not show the actual RU 1 What is needed for the connector assembly a Torque wrench b Adjustable counter wrench 2 Join the connectors and turn the coupling nut un...

Page 29: ...m 18 0 ps nm km 1550 nm Fibre cable connectors E2000 APC 8 ION M system The pigtails for the connection between Master Unit and Remote Unit must have a sufficient length Protection for the optical fib...

Page 30: ...ts dirt on the ferrule and scratches Connect the fiber optic cables by inserting the cable end into the laser receptacle and aligning the key on the cable end with the keyed slot Do not use any index...

Page 31: ...ng followed immediately with a dry clean in order to ensure no residue is left on the endface 8 Repeat steps 5 through 7 until endface is clean Note For a more detailed description please refer to htt...

Page 32: ...tor must be fitted into the stamp of the plug To release the contact for disassembling push the inner snap to the side and pull the contact out To release upper and lower insulation bodies for disasse...

Page 33: ...or disassembling release the clamping ring and remove the seals and the plastic ring first Locking mechanism The system of locking the plug is based on a push pull mechanism The locking ring has to be...

Page 34: ...lace the appropriate seal parts with one groove for one contact or two grooves for two contacts over the cable s and push them into the backshell Protective tube Reducer Coupling Protective plug Fiber...

Page 35: ...section 7 3 Spare Parts Subminiature circular connectors series 712 with five and seven contacts which are contained in the alarm kit can be ordered directly from the Binder Connector Group the manufa...

Page 36: ...monitor alarms with an external alarm indicator The 28 V pin pin 6 7 is specified to 28 VDC 0 5 A and is protected by a thermoswitch In case of exceeding this current between pin 7 and GND the thermo...

Page 37: ...y Note Observe the applicable national regulations regarding loop impedance voltage drop and methods of installation Make sure to connect the correct voltage to the unit Note Do not connect or disconn...

Page 38: ...r between mains and RU RF connection Connect antenna cable to antenna port Optical connections Mount the optical fibre with E2000 APC8 connector into the connector Plug the connector into the RU Mecha...

Page 39: ...power of affected band VSWR alarm Check antenna and cable LED status Proceed to MU to set up the SW Orange Yes Internal Error Change power supply RUs with a door Reduce environmental temperature Elim...

Page 40: ...only Check externally connected devices Optical alarm Rx RU only Check fibre loss of optical link Check optical connectors Clean optical connectors MU Check optical output power of corresponding OTRx...

Page 41: ...als on the modules to maintain warranty Please keep these guidelines in mind during maintenance The spare parts list consequently contains only units which can be replaced without tuning or soldering...

Page 42: ...s the instructions in section 6 1 General before starting with the replacement 1 Switch off the Remote Unit Make sure mains is disconnected for the following replacement procedure Then proceed as foll...

Page 43: ...he earth bonding cable and the fan connector see step 4 Then place the fan unit back into its original position and fasten it tight as shown below 6 Screw the whole fan unit to the cabinet with the fo...

Page 44: ...ate with the fan unit from the Remote Unit as described in section 6 2 Replacing the Fan Unit steps 1 and 2 3 Use compressed air max 5 bar to blow out the heat sink from back to front 4 In case the di...

Page 45: ...7 Appendix Manual MF0145AXA doc Manual for ION M17P 19P Advanced Page 45 7 Appendix 7 1 Illustrations figure 7 1 Cabinet drawing...

Page 46: ...B to 10 dB 7 2 2 Environmental and Safety Specifications Note For detailed information please refer to the Environmental and Safety Specifications leaflet of the supplier related to ETS 300 019 Europe...

Page 47: ...t of the Remote Unit ION M17P 19P Advanced Designation ID No ION M17P 19P Advanced 7707254 Protective Plug E2000 7160013 Protective Cap E 2000 7158914 Fan Protection Kit 7159097 Fan Unit 7158254 Prote...

Page 48: ...lug 31 Protective Tube Kit 33 Contact Addresses Customer Support 11 D Declaration of Conformity DoC 10 E External Alarm Inputs Outputs 35 F Fiber Optical Components Installation Cleaning 30 Flange Con...

Page 49: ......

Reviews: