4. Commissioning
Page 18
Manual
MF0145AXA.doc
Manual for ION-M17P/19P Advanced
4.1.4. Pole
Mounting
Standard mounting hardware cannot be used to mount the Remote Unit to a pole, a
column or other similar structures. Additional hardware must be used for this type of
installation. Such a pole-mounting kit could include two threaded rods M8, two
U-beams and mounting material like bolts and nuts.
figure 4-2 Pole-mounting kit
Use the screw bands to fasten the two U-beams to the pole as illustrated in
figure
4-3 Pole mounting
.
Note:
When fastening the U-beams make sure that they are installed
congruently and not at an angle to each other. To determine the distance
between the beams refer to chapter
4.1.3 Wall-Mounting Procedure
for
measurements.
Hang the mounting brackets of the Remote Unit into the threaded bolts of the
U-beam, and fasten them immediately using the washers and nuts.
Ensure that there is free access to the electrical connections as well as to the
cabinet. The approved bending radius of the connected cables must not be
exceeded.