background image

GROUND POLE INSTALLATION (1.2m System)

4

MIN.
DIA.

d

d

MIN.
DIA.

ANT

2.88" or

3.00" O.D.

2.88" or

3.00" O.D.

40"

C

L

72"

35.8"

35.8"

increased,

72"

40.9"

50" depth may be

will increase

length of rebar

concrete and

accordingly.

2"

2"

50"

NOTE:

#3 REBAR x DIA. OF PIER, INSERT

FROST LINE

#3 REBAR x

DIA. OF PIER

INSERT THRU HOLE

IN TUBE & CENTER

AT 90

o

APART

(SEE NOTE)

(4)#3x24"MIN.

BELOW

THRU HOLE IN TUBE & CENTER

1" to 2"

WATER RUN OFF

GRADE

SLOPE FOR

BELOW

FROST LINE

APPROX.

1" to 2"

SLOPE FOR

(SEE

NOTE)

GRADE

WATER RUN OFF

GROUND

ANT

WIND VEL.

DIM “d”

CONC VOL.

DIM “d”

CONC VOL.

DIM “d’

CONC VOL. DIM “d” CONC VOL.  POLE 

80 MPH

8”

1.3 

13”

3.4 

8”

1.6

10”

2.5

“A” or

90 MPH

10”

2.0 

16”

5.1 

8”

1.6

12”

3.6

“B”

1.2M

100 MPH

12”

2.9 18”

6.5  8”

1.6

13”

4.2

“B” or

LFL

110 MPH

14”

3.9 

21”

8.8 

10”

2.5

16”

6.4

“C”

125 MPH

17”

5.8 

24”

11.5 12”

3.6

19”

9.0

“D”

POLE SPECIFICATIONS:

Ground Pole “A” = 2.88 O.D. x .154 Wall (Sch 40) x 72” ASTM A53 or A501 Pipe 
Ground Pole “B” = 3.00 O.D. x 9 Ga. (.148 Wall) x 72” Steel - CM PN 611685101
Ground Pole “C” = 2.88 O.D. x 2.88 O.D. x .276 Wall (Sch 80) x 72” Steel ASTM A53 or A501 Pipe 
Ground Pole “D” = 3.00 O.D. x .250 Wall x 72” Steel ASTM 120 Mech Tubing

NOTE:

Pole “B” is supplied from factory powder painted and with hole for #3 rebar and grounding screw.

Poles “A”, “C” and “D” are not supplied and must be field drilled 

⁵⁄₈

” dia. for #3 rebar and drilled .218 

for 

¹⁄₄

-20 self tapping grounding screw and galvanized or painted for protection.

1 - Pole and foundation design based on the following criteria:

a) Uniform building code exposure B or C and 1.5 stability factor.
b) Vertical soil pressure of 2000 pounds per square foot.
c) Lateral soil pressure of 400 pounds per square foot.
d) Concrete compressive strength of 2500 pounds per square inch in 28 days.

2 - 

CAUTION

- The foundation design shown does not represent an appropriate design for any specific locality since soil conditions vary

and may not meet design criteria given in Note 1. You should consult a local professional engineer to determine your soil conditions
and appropriate foundation.

Exposure “B”

Exposure “C”

Exposure “B”

Exposure “C”

PIER FOUNDATIONS

DEEP FROST LINE FOUNDATIONS

Bubble
Level

Ground Pole
Must Be
Vertical In
All Directions
Within .19 Inches
At Top (0.3ß)

13

Mo Based on 40.9" (1039 mm) from Mounting Surface of Center Line of Antenna

Values shown represent maximum forces for any wind direction and 
include 1.5 Fs. Height and exposure factors from uniform building code

are NOT included.

APPENDIX B

1.2m Antenna Survival Windloads at 125 MPH Velocity

BE

AM

AX

IS

MECHANICAL AXIS

(NORMAL TO ANTENNA FACE)

16.97

o

OFFSET

40.9" HEIGHT
  (1039 mm)

FH

MT

FV

FH = Horizontal Force
FV = Vertical Force
MT = Torsional Moment
MO = Overturning Moment

MO

ELEVATION DEGREES

MECHANICAL

BEAM

0

17

10

27

20

37

30

47

40

57

50

67

60

77

70

87

FORCE (POUNDS)

F

H

F

V

1285

-35

1217

-257

1182

-497

1071

-711

943

-857

822

-943

686

-985

515

-762

MOMENTS (FT-LBS/N-m)

M

T

M

O

500

4,380

488

4,148

464

4,029

421

3,650

357

3,214

299

2,802

232

2,338

178

2,096

Summary of Contents for 123 Class I

Page 1: ...SA Customer Support Center From North America Telephone 1 800 255 1479 Fax 1 800 349 5444 satcom andrew com One Company A World of Solutions International Telephone 1 708 873 2307 Fax 1 708 349 5444 I...

Page 2: ...iately upon failure Non compliance with any part of this claim procedure may invalidate this warranty in whole or in part THIS WARRANTY IS EXPRESSLY IN LIEU OF ALL OTHER AGREEMENTS AND WARRANTIES ANY...

Page 3: ...required before installing an antenna It is the property owner s responsibility to obtain any and all permits Before any digging is done information regarding the possi bility of underground telephone...

Page 4: ...foot c Lateral soil pressure of 400 pounds per square foot d Concrete compressive strength of 2500 pounds per square inch in 28 days 2 CAUTION The foundation design shown does not represent an approp...

Page 5: ...protection 1 Pole and foundation design based on the following criteria a Uniform building code exposure B or C and 1 5 stability factor b Vertical soil pressure of 2000 pounds per square foot c Late...

Page 6: ...lector and insert exposed portion of bolt to holes in Antenna Bracket Flange Install 4 Lock Washers and Hex Nuts on bolts Ref Fig 1 2 Assemble Extension Plate to AZ EL Housing using two M6 x 22mm Roun...

Page 7: ...nd Hex Nuts Round Head Square Bolt fits on the underside of Mount Housing top flatten end of Brace on top side of Mount Housing Tooth Lock Washer on top of flatten end of Brace then Flat Washer and He...

Page 8: ...or and Support Block to 4 ft lbs 5 4 N m Tighten and torque M6 x 55mm U Bolt to 18 22 in lbs 2 2 5 N m TOOTH WASHER BLOCK U CLIP BRACE SIDE FEED LEGS 2 REQ RD HD SQ NK BOLT ELASTIC LOCK NUT BOTTOM FEE...

Page 9: ...ion and counterclockwise to increase elevation Align the edge of the Clamp with appropriate mark on housing at the desired elevation reading This will be an approximate setting Optimum setting achieve...

Reviews: