background image

Printed in U.S.A.
 
8/06   8000842-01 Rev B 

Assembly Instructions

8000842-01

Type 960 Class I & II .96 Meter Antenna System
Type 123 Class I & II 1.2 Meter LFL Antenna System

with Factory Assembled Az/El Cap Mount

Andrew Corporation
3 Westbrook Corporate Center
Suite 900
Westchester, Illinois  60154 USA

Customer Support Center
From North America

Telephone: 1-800-255-1479

Fax: 1-800-349-5444

[email protected]

One Company. A World of Solutions.

International

Telephone: +1-708-873-2307

Fax: +1- 708-349-5444

Internet:

 www.andrew.com

DO NOT DISCARD CONTENTS

The product in this packaging was placed in the market after August 13, 2005.  Its components must not be discarded with 
normal municipal or household waste.

Contact your local waste disposal agency for recovery, recycling, or disposal instructions.

Summary of Contents for 123 Class I

Page 1: ...SA Customer Support Center From North America Telephone 1 800 255 1479 Fax 1 800 349 5444 satcom andrew com One Company A World of Solutions International Telephone 1 708 873 2307 Fax 1 708 349 5444 I...

Page 2: ...iately upon failure Non compliance with any part of this claim procedure may invalidate this warranty in whole or in part THIS WARRANTY IS EXPRESSLY IN LIEU OF ALL OTHER AGREEMENTS AND WARRANTIES ANY...

Page 3: ...required before installing an antenna It is the property owner s responsibility to obtain any and all permits Before any digging is done information regarding the possi bility of underground telephone...

Page 4: ...foot c Lateral soil pressure of 400 pounds per square foot d Concrete compressive strength of 2500 pounds per square inch in 28 days 2 CAUTION The foundation design shown does not represent an approp...

Page 5: ...protection 1 Pole and foundation design based on the following criteria a Uniform building code exposure B or C and 1 5 stability factor b Vertical soil pressure of 2000 pounds per square foot c Late...

Page 6: ...lector and insert exposed portion of bolt to holes in Antenna Bracket Flange Install 4 Lock Washers and Hex Nuts on bolts Ref Fig 1 2 Assemble Extension Plate to AZ EL Housing using two M6 x 22mm Roun...

Page 7: ...nd Hex Nuts Round Head Square Bolt fits on the underside of Mount Housing top flatten end of Brace on top side of Mount Housing Tooth Lock Washer on top of flatten end of Brace then Flat Washer and He...

Page 8: ...or and Support Block to 4 ft lbs 5 4 N m Tighten and torque M6 x 55mm U Bolt to 18 22 in lbs 2 2 5 N m TOOTH WASHER BLOCK U CLIP BRACE SIDE FEED LEGS 2 REQ RD HD SQ NK BOLT ELASTIC LOCK NUT BOTTOM FEE...

Page 9: ...ion and counterclockwise to increase elevation Align the edge of the Clamp with appropriate mark on housing at the desired elevation reading This will be an approximate setting Optimum setting achieve...